5.

 

Technical Specifications 

 

5.1

 

Electrical Connections 

5.1.1

 

Motor Pinout & Cable 

 

Pin 

Description 

Motor Phase A+ 

Motor Phase A- 

Motor Phase B+ 

Motor Phase B- 

Limit Switch Common 

Limit Switch 

 (near motor) 

Limit  

Thermal Element - 

Thermal E 

 

For  compatibility  with  MICRONIX  USA  controllers,  Pin  5,  7  and  shield  are 
internally  connected.  Negative  limit  only,  positive  limit  is  connected  to 
Ground. 
Limit  Switch  Common  (pin  5)  is  connected  to  ground  in  MICRONIX  USA 
controllers. 

 

5.1.2

 

Stepper Motor  

 

Motor Type 

2 Phase Bipolar 

Phase Current 

1.2 A max. 

Step Angle 

1.8 ° 

Steps 

200 

Leadscrew Pitch 

0.5 mm/rev 

Gear Reduction 

4:1 

Resolution/Fullstep 

0.625 µm 

 

Summary of Contents for MPA-20 series

Page 1: ...S e r i e s Reference Manual Micro Precision Actuator UHV MPA 20...

Page 2: ...MPA 20 Linear Actuator Reference Manual Rev 1 01 MICRONIX USA LLC 15375 Barranca Parkway E 106 Irvine CA 92618 Tel 949 480 0538 Fax 949 480 0538 Email info micronixusa com http micronixusa com...

Page 3: ...bers 4 3 Preparing to Install the MPA 20 5 3 1 Installation Preparation 5 3 2 Package Contents 5 4 Installing the MPA 20 6 4 1 MPA 20 12 mm Installation 6 5 Technical Specifications 7 5 1 Electrical C...

Page 4: ...manual drive stages and mirror mounts It utilizes a 2 phase stepper motor and two mechanical limit switches The MPA 20 is compatible with the MMC 200 controller Features Travel range of 12 mm Gear red...

Page 5: ...Technical Data Motor SM 005 Screw Pitch mm 0 5 Gear Ratio 4 1 Speed Max mm sec 1 25 Resolution Calculated m 0 625 with micro stepping Resolution Typical m 0 1 Bi directional Repeatability m 1 Uni dir...

Page 6: ...MICRONIX USA LLC Irvine California www micronixsusa com 2 Model Configurations 2 1 MPA 20 Order Numbers Contact MICRONIX USA for custom versions Order No MPA 20 1 1 0 1 9 SM 005 1 12 mm 1 No Encoder...

Page 7: ...face which is free of debris burrs or dings An indoor atmosphere free of corrosive gases excessive dust and condensation Temperature range of 0 40 C Relative humidity between 20 80 Locate away from wa...

Page 8: ...applying torque to the housing In place of the spherical actuator tip a 4 40 thread may be used for pulling applications When preparing the stage for vacuum environments take the necessary precautions...

Page 9: ...itch Common 6 Limit Switch near motor 7 Limit Switch 8 Thermal Element 9 Thermal Element For compatibility with MICRONIX USA controllers Pin 5 7 and shield are internally connected Negative limit only...

Page 10: ...PA 20 Linear Actuator The mechanical limit switches are factory calibrated for a minimum travel of 12mm when the switches are initially activated Customer adjustment of the limit switches is not recom...

Page 11: ...MPA 20 Micro Precision Actuator Rev 1 01 9 Reference Manual MICRONIX USA LLC Irvine California www micronixsusa com 5 3 Dimensions 5 3 1 MPA 20 12 mm...

Page 12: ...he actuator is in motion to avoid personal injury Follow the Safe Operating Environment requirements and use proper cable management to ensure a clean and safe operating environment The MPA 20 is desi...

Reviews: