background image

MICRON

12.

When the power is switched off, the unit will briefly continue to blow cooling air through the pipe. Do not
disconnect the plug during this cooling process.

13.

Do not leave the machine unattended while switched on and operating. Turn off the machine and unplug
the power cord when you are leaving and put the hot air nozzle in the holder on one side of the machine.
Always replace the hand tool in its holder when not being used. The nozzle and the heating element 
remain hot after being switched off.

14.

Do not use if damaged: If the pump stops working or the rework station becomes faulty, immediately 
discontinue using the unit. Only authorized technicians are able to safely repair the unit or replace

parts. 

Do not disassemble the pump.

TO PREVENT ELECTRICAL SHOCK, TAKE THESE PRECAUTIONS: 

1.

Death or serious injury may result from electric shock. It is therefore essential to isolate the equipment 
from the mains before commencing maintenance or repairs. Remember to unplug in the power cord. 

2.

Always connect the unit to a grounded power socket. 

3.

Do not pour water/liquids or subject the heating surface to physical shock. This may damage the heater.
Avoid contact with moisture.

4.

The station must be switched off and the power cord must be unplugged before replacing the fuse in the 
AC socket at the rear side of the machine. 

5.

Turn the power switch off and remove the AC power cord by pulling the plug (not the cable) when the 
unit will remain unused for a long period of time. 

PRODUCT FEATURES:

?

Specially-designed intelligent chip microcomputer control system

?

Easy to read digital LED displays with simple to use operating buttons to control temperature and air flow. 

?

The temperature can be locked by a “password” code that is convenient for production line management.

?

Quick heating high-power heating element, with a maximum of 600W.

?

Ideally suited to desoldering ICs such as: QFP, SOP, PLCC or SOJ chips etc.

?

The built in static-free circuit design is safe for the sensitive circuit components elements like CMOS ICs.

?

Auto shutoff handpiece cradle (Air power is shut off when handpiece is placed in cradle)

?

Auto-cooling design: When the power is switched off, the cooling system begins automatically, and the 
temperature will drop gradually down to 100 degrees Celsius (212°F) to protect the heating element from 
burning out.

?

Sensor / Pump Failed Detection - If the sensor circuit fails, the display reads ‘S-E’ and the power to the 
heating nozzle is cut. If the pump circuit fails, the display reads ‘P-E’ and the power is cut to the heating 
nozzle.

?

Heating element auto-protecting function: When the heating element reaches a high temperature, this 
function automatically protects the element, and thereby preventing the element from premature failure.

INSIDE THE BOX:

?

T 1287 Workstation and air pump handle / pencil.

?

Nozzles: 10mm x 10mm; 14mm x 14mm; 4mm dia; 7mm dia. 

?

Pliers (Tweezer) – 4 different sets, non-magnetic stainless steel.

?

Heating elements.

?

IC removing wire tool.

PRODUCT DESCRIPTION

The temperature-controlled LF-852DII Hot-Air SMD rework station has been built around an intelligent
microcomputer chip, which is specially designed to work with lead free SMD chips such as SOIC, CHIP, QFP,
PLCC, BGA etc.  It also meets RoHS standards requirement. This appliance is equipped with a high-power
heating element that heats up quickly. High-quality sensors and consistent heat-transfer technology ensure
precise temperature regulation. The aluminum housing is strong and acts as a reliable heat sink and is
resistant to electro-magnetic interference.

3

Summary of Contents for T 1287

Page 1: ...p Suits leaded lead free solder RoHS Quality heating element Rapid heat up Long service life Includes 4 nozzles SMD tweezer set chip removal tool spare heating element Individual temperature air flow adjustments Auto fan cooling extends tip life ESD safe Energy authority approved ...

Page 2: ... The surface should be made of fire and heat resistant material because the unit can reach very high temperatures and is potentially dangerous 4 During the operation the heater is extremely hot and will cause serious burns if it makes contact with exposed skin Use gloves and or any other heat resistant tools to pick up the PCB assembly to eliminate the possibility of accidental burns 5 Do not touc...

Page 3: ...and air flow The temperature can be locked by a password code that is convenient for production line management Quick heating high power heating element with a maximum of 600W Ideally suited to desoldering ICs such as QFP SOP PLCC or SOJ chips etc The built in static free circuit design is safe for the sensitive circuit components elements like CMOS ICs Auto shutoff handpiece cradle Air power is s...

Page 4: ...edge of the nozzle with pliers Also do not tighten the set screw too tightly 3 In order to protect the pump during transportation the pump in the machine is tightened by the 4 screws under the bottom enclosure Please unscrew the 4 screws before the machine is first used See Figure 2 above 4 Ensure that the base unit power switch is in the off position Check carefully for any damage that may have o...

Page 5: ...meter required NOTE that the unit returns to normal operation after 15 seconds if no key is pressed TEMPERATURE ADJUSTMENT LOCKOUT SETTING When the LED displays F 1 and flashes press SET key and the unit enters the temperature adjustment lockout status At this moment the LED displays the preset value If 000 is set this means the unit has no temperature lock Press or key to change temperature adjus...

Page 6: ...liers tweezers 3 Turn the power switch off After the power switch is off an automatic blowing function begins sending cool air through the pipe in order to cool both the heating element and the handle So do not disconnect the plug during this cooling process 4 In case you don t use the unit for a long time disconnect the plug NOTE About a minute after the power is switched off the temperature will...

Page 7: ...MICRON 7 ...

Page 8: ...e Note Under no circumstances should you attempt to repair the player yourself or via a non authorised Altronics service centre as this will invalidate the warranty During the warranty period we undertake to repair or replace your product at no charge if found to be defective due to a manufacturing fault The warranty excludes damage by misuse neglect shipping accident incorrect installation or no ...