23
MICRON AU8115MS VEHICLE MOUNTED SPRAYER
Engine starter,
throttle actuator and
indicator lights on
control box do not
function
Battery cable disconnected
Battery fuse blown
CONTROLS circuit breaker
tripped
Check connector and battery
cables
Locate fault and replace fuse
(100 A)
Locate fault and reset
CONTROLS circuit breaker
Engine throttle does
not move between
maximum and
minimum settings
when THROTTLE
switch is actuated
Throttle cable loose at
linkage to engine
Electric throttle actuator
defective
Check and adjust clamp on
outer part of cable and/or
screw securing inner part of
cable
Service or replace throttle
actuator