— 14 —
CPD-2401
4-7. Digital Convergence Adjustment
Convergence (Low) Mode
1. Adjust the H.STAT and V.STAT with "HSTAT" and
"VSTAT".
A. Horizontal Convergence
9
11
19
17
1
10
12
20
18
2
5
6
CBH-T-L-LO
MBH-T-L-LO
APH-L-LO
MBH-B-L-LO
CBH-B-L-LO
CBH-T-R-LO
MBH-T-R-LO
APH-R-LO
MBH-B-R-LO
CBH-B-R-LO
YBH-T-LO
YBH-B-LO
HSTAT
Adjust each misconvergence point in sequence.
B. Vertical Convergence
13
15
23
21
3
14
16
24
22
4
7
8
CCV-T-L-LO
MCV-T-L-LO
XBV-L-LO
MCV-B-L-LO
CCV-B-L-LO
CCV-T-R-LO
MCV-T-R-LO
XBV-R-LO
MCV-B-R-LO
CCV-B-R-LO
V STAT-T-LO
V STAT-B-LO
VSTAT
Adjust each misconvergence point in sequence.
2. Repeat the procedure of A and B so that the convergence
of the entire screen is within the specification.
Convergence (High) Mode
1. Adjust the H.STAT and V.STAT with "HSTAT-HI" and
"VSTAT-HI".
Horizontal Convergence
9
11
19
17
1
10
12
20
18
2
5
6
CBH-T-L-HI
MBH-T-L-HI
APH-L-HI
MBH-B-L-HI
CBH-B-L-HI
CBH-T-R-LHI
MBH-T-R-HI
APH-R-HI
MBH-B-R-HI
CBH-B-R-HI
YBH-T-HI
YBH-B-HI
HSTAT-HI
Adjust each misconvergence point in sequence.
Vertical Convergence
13
15
23
21
3
14
16
24
22
4
7
8
CCV-T-L-HI
MCV-T-L-HI
XBV-L-HI
MCV-B-L-HI
CCV-B-L-HI
CCV-T-R-HI
MCV-T-R-HI
XBV-R-HI
MCV-B-R-HI
CCV-B-R-HI
V STAT-T-HI
V STAT-B-HI
VSTAT-HI
Adjust each misconvergence point in sequence.
2. Repeat the procedure of A and B so that the convergence
of the entire screen is within the specification.
4-8. Convergence Specification
B
C
A
312 mm
234 mm
A Zone:
Primary Mode
H: < 0.25mm
V: < 0.2mm
B Zone:
Primary Mode
H: < 0.3mm
V: < 0.3mm
C Zone:
Primary Mode
H: < 0.35mm
V: < 0.35mm
Others
H: < 0.3mm
V: < 0.3mm
Others
H: < 0.4mm
V: < 0.4mm
Others
H: < 0.4mm
V: < 0.4mm