Specifying Sample Defaults
Gemini VII
3-4
239-42828-01 - Dec 2012
Basic Format
When specifying defaults in the Basic format, select from existing default parameters. The defaults
established in Basic format also serve as defaults for files created using the Restricted format.
To define parameter files before entering sample defaults in Basic format, refer to
Perform the following steps to establish defaults for a sample information file in the Basic format.
1.
To change to Basic format, go to
Options > Option Presentation > Basic
.
2.
Go to
Options > Sample Defaults
.
3.
In the
Sequence Number
alpha/numeric text box, specify a default file name string. The
Sequence Number
field must contain a minimum of three (3) numbers. This number is
incrementally sequenced and displays in the
File name
text box in the
File > Open > Sample
Information
window.
4.
The text box to the right of the
Sample
field, is used to enter a format for the sample
identification. Include the
$
symbol to automatically include the
Sequence Number
field text as
part of the sample identification.
5.
In the
Mass
group box, enter default values for the sample’s mass and density. Both of these
values may be edited at the time of analysis. Refer to
The field label for the Sample field can be modified by overwriting the default field label.
Summary of Contents for Gemini VII 2390a
Page 1: ...Gemini VII Operator s Manual V3 02 239 42828 01 Jan 2014...
Page 4: ......
Page 12: ...Table of Contents Gemini VII viii 239 42828 01 Nov 2013...
Page 36: ...Menu Structure Gemini VII 2 14 239 42828 01 Dec 2012...
Page 192: ...Service Test Gemini VII 6 24 239 42828 01 Dec 2012...
Page 217: ...Gemini VII Report Examples 239 42828 01 Dec 2012 7 25 Isotherm Linear Plot...
Page 218: ...Report Examples Gemini VII 7 26 239 42828 01 Dec 2012 BET Surface Area Report...
Page 219: ...Gemini VII Report Examples 239 42828 01 Dec 2012 7 27 BET Surface Area Plot...
Page 220: ...Report Examples Gemini VII 7 28 239 42828 01 Dec 2012 t Plot...
Page 221: ...Gemini VII Report Examples 239 42828 01 Dec 2012 7 29 BJH Adsorption Cumulative Pore Volume...
Page 222: ...Report Examples Gemini VII 7 30 239 42828 01 Dec 2012 BJH Adsorption dV dlog w Pore Volume...
Page 264: ......
Page 266: ......
Page 294: ...Appendix B Gemini VII B 28 239 42828 01 Nov 2013...
Page 364: ...Appendix F Gemini VII F 18 239 42828 01 Dec 2012...
Page 372: ...Gemini VII Smart VacPrep Operator Manual Dec 2013 G 1 G Smart VacPrep Operator Manual...
Page 380: ...Contact Us vi Smart VacPrep Operator Manual...
Page 390: ...2 About the Software 2 4 Smart VacPrep Operator Manual...
Page 424: ...8 Error Messages 8 4 Smart VacPrep Operator Manual...