A069 L2 Service Manual
RECEIVER LOW VOICE OR NO VOICE
Measure the signal
with oscillograph
under calling mode
Receiver is low.
Check if receiver
connector is damaged.
Resolder or clean the
receiver connector.
Check if the receiver is
broken or damaged
Yes
NO
NO
Replace the
receiver.
Replace the PCBA.