Micromark MM23052 Installation & Operating Instructions Manual Download Page 9

9

SYSTEM ENTRY TIME

Then P

Prre

essss  P

P  2

2  EE  and within 5

seconds your choice.
((IIff  yyo

ou

u  d

do

o  n

no

ott  d

de

ecciid

de

e  w

wiitth

hiin

n  5

5

sse

ecco

on

nd

dss,,  tth

hrre

ee

e  ssh

ho

orrtt  b

blle

ee

ep

pss

w

wiillll  b

be

e  h

he

ea

arrd

d,,  a

an

nd

d  yyo

ou

u  w

wiillll

h

ha

avve

e  tto

o  e

en

ntte

err  P

P  2

2  EE  a

an

nd

d  sstta

arrtt

a

ag

ga

aiin

n..))

Then P

Prre

essss  P

P  0

0  EE  to exit

programming. 

1

2

3

4

Entry time is the period
of time allowed for you
to enter and disarm the
system with the
password (factory set to
1122), before the sirens
sound. 

The entry time is set by
the factory to 20
seconds but this can be
changed from a choice
of 7 other entry times to
suit you. 

If for any reason the
sirens sound, p

prre

essss

11112

22

2  to disarm.

P

Prre

essss  3

3  EE which is the

program for 40 seconds.

If entered correctly, a
continuous bleep will be
heard for 2 seconds. 

For example, to change the
entry time to 40 seconds (see
choices in Table): 
P

Prre

essss  P

P  11112

22

2  EE  tto

o  e

en

ntte

err

p

prro

og

grra

am

mm

miin

ng

g..

SYSTEM EXIT TIME

Exit time is the period of
time allowed for you to
exit after arming the
system with the
password, before the
sirens sound. 

The exit time is set by
the factory to 15
seconds but this can be
changed from a choice
of 7 other exit times to
suit you. 

If for any reason the
sirens sound, p

prre

essss

11112

22

2  to disarm.

1

For example, to change the
exit time to 60 seconds (see
choices in Table): 
P

Prre

essss  P

P  11112

22

2  EE  tto

o  e

en

ntte

err

p

prro

og

grra

am

mm

miin

ng

g..

Then P

Prre

essss  P

P  3

3  EE  and within 5

seconds your choice.
((IIff  yyo

ou

u  d

do

o  n

no

ott  d

de

ecciid

de

e  w

wiitth

hiin

n  5

5

sse

ecco

on

nd

dss,,  tth

hrre

ee

e  ssh

ho

orrtt  b

blle

ee

ep

pss

w

wiillll  b

be

e  h

he

ea

arrd

d,,  a

an

nd

d  yyo

ou

u  w

wiillll

h

ha

avve

e  tto

o  e

en

ntte

err  P

P  3

3  EE  a

ag

ga

aiin

n..))

2

3

P

Prre

essss  4

4  EE  which is the

program for 60 seconds.

If entered correctly, a
continuous bleep will be
heard for 2 seconds.

Then P

Prre

essss  P

P  0

0  EE  to exit

programming. 

4

Example:

Example:

To choose other entry times:
11EE

10 seconds

0

0EE

15 seconds

2

2EE

20 seconds

3

3EE

40 seconds

4

4EE

60 seconds

5

5EE

90 seconds

6

6EE

120 seconds

77EE

240 seconds

To choose other exit times:
11EE

10 seconds

0

0EE

15 seconds

2

2EE

20 seconds

3

3EE

40 seconds

4

4EE

60 seconds

5

5EE

90 seconds

6

6EE

120 seconds

77EE

240 seconds

ukpanels.com

Summary of Contents for MM23052

Page 1: ...requirements of each Authority differ we suggest that you contact the Environmental Officer of your local Borough for full information about your local area s by laws C CO ON NT TE EN NT TS S Planning...

Page 2: ...system over a long period In the event of an activation during a power loss period all of the zone LEDs will illuminate when you disarm the system You will have to reset the system using your persona...

Page 3: ...ON AND COVER WITH TAPE TERMINAL BLOCK BLACK WIRES TWISTED AND TAPED TOGETHER BLACK WIRES TWISTED AND TAPED TOGETHER RED WIRES TWISTED AND TAPED TOGETHER 3 WAY TERMINAL BLOCK FROM CONTROL PANEL FROM CO...

Page 4: ...iring and pipework When planning the wiring avoid awkward cable runs to the control panel siren box PIRs and door contacts 1 Install the control panel out of reach of young children Mark for two verti...

Page 5: ...g the cable to the position of the siren box and cut the cable allowing enough surplus for wiring into the siren terminal block Strip the wires and connect them to the teminal block as shown Fix the s...

Page 6: ...e insulation and tape the end 5 Follow the same procedure for each of the zones At the control panel mark the w wi ir re es s w wi it th h t th he e z zo on ne es s f fr ro om m w wh hi ic ch h t th h...

Page 7: ...OT TE E T To o m ma aiin nt ta aiin n o op pt tiim mu um m s se ec cu ur riit ty y t th he e b ba at tt te er ry y s sh ho ou ulld d b be e c ch he ec ck ke ed d r re eg gu ulla ar rlly y a an nd d r...

Page 8: ...E E t to o e en nd d t te es st t The internal buzzer will temporarily sound a constant tone for 3 seconds The control panel returns to programming mode with flashing STATUS LED P Pr re es ss s P P 0...

Page 9: ...ou to exit after arming the system with the password before the sirens sound The exit time is set by the factory to 15 seconds but this can be changed from a choice of 7 other exit times to suit you I...

Page 10: ...e external siren will stop after the programmed time but the internal siren will beep slowly until the password has been entered The bell reset time is set by the factory to 10 minutes but this can be...

Page 11: ...d a ag ga ai in n t to o r re es se et t 1 You can programme a zone to activate as a chime tone This is useful if the system is not fully armed but you need to know of unauthorised entry in a particul...

Page 12: ...p po ot te en nt ti ia al l n ne eg ga at ti iv ve e c co on ns se eq qu ue en nc ce es s f fo or r t th he e e en nv vi ir ro on nm me en nt t a an nd d h hu um ma an n h he ea al lt th h w wh hi ic...

Reviews: