1. Start the test at least 2 minutes after connecting power supply
3 .Testing in different direction to confirm the two boundaries of the
coverage, ensure the detector is appoint to the central desired area.
4. At 6m away from diliclor , raise slowly your arm and reach
into the detection zone, mark the lower limit of PIR detection. Do
the same step to confirm the upper limit.
5.the center of detection zone should not uphill incline. To obtain a
good detection range , please adjust the vertical detection range, en-
sure the detector is in a correct position.
2. Walking breadthwise at the remote and of the detection coverage
at the speed of 0.75m/s within 3m, then will trigger the detector and
the LED indications 2-3seconds.
6. After MW sensitivity or detection angle are adjusted, walking test
must be performed according to the above steps.
: after charge or the temper proof switch been pressed, the detector do self checking for 30 seconds then it get a period time
of 6 minutes for test. Within the test period, the human body moves according to the set direction until the system alarms, then
the indicating light lights and sends out the wireless alarm signal.
: after the testing period of 6minutes, it is the working period. Within this period, the human body moves according to the set
direction (such as enter into the room), if the LED ON is opened, then the indicating light lights and sends out the wireless
alarm signal. Then close the alarm, and test to see if any body is moving, until to the set alarm start up time, the system does
not detect the body movement, and confirmed to be away, then the detector can be started again.
When the human body moves against to the set direction (such as leave the room), the system does not alarm, Then close the
alarm, and test to see if any body is moving, until to the set alarm start up time, the system does not detect the body movement,
and confirmed to be away, then the detector can be started again.
After the reposition of the dismantle proof and magnetic switch on the detector, you will then get a period time6 minute for test. Within this time,
after the finish of automatic test, you can arrange the walking test. 6 minute later, the system enters into the working period. After one time alarm
within the working period, the system will check if there is any non-human activity for 140 seconds. Only after confirming that there is no human
activity for 140 seconds continuously, the detector will then start up the detecting model.
The testing period and working period
Special notice:
Testing period
Working period
3.10
Perform walking test to the detection area: install the cover and close the fasten part
(refer to the right diagram)
Important mention: Motion test shall be performed at least one time each
week in order to guarantee that each detector can keep excellent function.
Even the most sophisticated detcetors can sometimes be defeated or may fail to warn due to :DC power failure/improper connection, malicious mask-
ing of the lens,tampering with the optical system, decreased sensitivity in ambient temperatures near that of the human body and unexpected fail-
ure of a component part.The above list includes the most common reasons for failure recommended that the detector and the entire alarm system be ch-
ecked weekly, to ensure proper performance.An alarm system should not be regarded as a substitute for insurance. Home & property owners or renters sh-
ouldbe prudent enough to continue insuring their lives & property, even though they are protected by an alarm system.
WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could
void the user s authority to operate the equipment.
This device has been tested and found to comply with the limits for a Class B digitaldevice, pursuant harmful interference in residential installations .This equipment
generates,uses and can radiate radio frequency energy and ,if not installed and used in accordance with the ins-tructions ,may cause harmful in-terference to radio and t-
elevision reception. However, there is no guarantee that interference will not occur in aparticular installation .If this device does cause such interference , which can be ver-
fied by turning the device off and on ,the user is encouraged to eliminate the interference by one or more of the followingmeasures:
- Increase the distance between the device and the receiver.
- Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
- Consult the dealer or an expericnced radio/TV technician.
4.Special comments