BP W3 Comfort

EN

3. Follow the instructions above to set the day, hour and minutes.

4. Once you have set the minutes and pressed the time button, the 

date and time are set and the time is displayed.

5. If you want to change the date and time, press and hold the time 

button down for approx. 3 seconds until the year number starts to

flash. Now you can enter the new values as described above.

2. Checklist for Taking a Reliable Measurement

1. Avoid activity, eating or smoking immediately before the measurement.

2. Sit down on a back-supported chair and relax for 5 minutes. Keep 

the feet flat on the floor and do not cross your legs.

3. Always measure in a sitting position and on the same wrist. Use 

the wrist which usually shows higher blood pressure values.

4. Remove any items of clothing and your watch, for example, so 

that your wrist is free.

5. Always ensure that the cuff is positioned correctly, as shown in the 

pictures illustrated on the short instruction card.

6. Fit the cuff comfortably but not too tight. The cuff will cover a wrist 

circumference of 13.5 - 23 cm (5.25 - 9.05 inches).

7. Support your arm in a relaxed position and ensure that the 

device 

is at the same height as your heart.

3. Taking a Blood Pressure Measurement

1. Press the ON/OFF button 

1

 to start the measurement.

2. The cuff fit check 

AO

 on the display indicates that the cuff is 

perfectly placed. If the icon 

AO

-A appears, the cuff is fitted subop-

timally, but it is still ok to measure.

3. The cuff will now pump up automatically. Relax, do not move and 

do not tense your arm muscles until the measurement result is 

displayed. Breathe normally and do not talk.

4. The measurement is performed during the inflation. The inflation 

speed may vary, this is a normal occurence.

5. During the measurement, the pulse indicator 

AP

 flashes in the display.

6. The result, comprising the systolic 

7

 and the diastolic 

8

 blood 

pressure and the pulse rate 

9

 is displayed. Note also the expla-

nations on further display symbols in this booklet.

7. Remove and switch off the monitor and enter the result in the 

enclosed blood pressure pass. (The monitor does switch off auto-

matically after approx. 1 min.).

You can stop the measurement at any time by pressing the 

ON/OFF button (e.g. if you feel uneasy or an unpleasant pres-

sure sensation). 

How not to store a reading

As soon as the reading is displayed press and hold the ON/OFF 

button 

1

 until «

M

» 

AK

 is flashing. Confirm to delete the reading by 

pressing the time button 

AK

.

«

CL

» is displayed when the reading is deleted from the 

memory successfully.

Summary of Contents for W3 Comfort

Page 1: ...olife com Asia Microlife Corporation 9F 431 RuiGuang Road NeiHu Taipei 11492 Taiwan R O C Tel 886 2 8797 1288 Fax 886 2 8797 1283 Email service microlife com tw www microlife com North Central South America Microlife USA Inc 1617 Gulf to Bay Blvd 2nd Floor SuiteA Clearwater FL33755 USA Tel 1 727 442 5353 Fax 1 727 442 5377 Email msa microlifeusa com www microlife com C C C ...

Page 2: ...arihi Fecha de compra Data da compra Datum van aankoop Ημερομηνία αγοράς Specialist Dealer Revendeur Categoria riven ditore Fachhändler Uzman satıcı Distribuidor especializado Revendedor autorizado Specialist Dealer Εξειδικευμένος αντιπρόσωποςa اﻟﻜﻔﺎﻟﺔ ﺑﻄﺎﻗﺔ اﻟﺨﻠﻔﻲ اﻟﻐﻄﺎء اﻧﻈﺮ اﻟﻜﻔﺎﻟﺔ ﺑﻄﺎﻗﺔ اﻟﻤﺸﺘﺮي اﺳﻢ اﻟﻤﻮدﻳﻞ اﻟﺘﺴﻠﺴﻞ رﻗﻢ اﻟﺸﺮاء ﺗﺎرﻳﺦ اﻟﻤﺨﺘﺺ اﻟﺘﺎﺟﺮ اﻟﻜﻔﺎﻟﺔ ﺑﻄﺎﻗﺔ اﻟﺨﻠﻔﻲ اﻟﻐﻄﺎء اﻧﻈﺮ اﻟﻜﻔﺎﻟﺔ ﺑﻄﺎﻗﺔ اﻟ...

Page 3: ...rs or older Dear Customer Thisdevicewasdevelopedincollaborationwithphysiciansandclinicaltests carried out prove its measurement accuracy to be of a very high standard If you have any questions problems or want to order spare parts please contact your local Microlife Customer Service Your dealer or pharmacy will be able to give you the address of the Microlife dealer in your country Alternatively v...

Page 4: ...replacement Which batteries and which procedure Using rechargeable batteries 6 Error Messages 7 Safety Care Accuracy Test and Disposal Safety and protection Device care Cleaning the cuff Accuracy test Disposal 8 9 Guarantee Technical Specifications 1 Using the Device for the First Time Inserting the batteries After you have unpacked your device first insert the batteries The battery compartment 5 ...

Page 5: ... height as your heart 3 Taking a Blood Pressure Measurement 1 Press the ON OFF button 1 to start the measurement 2 The cuff fit check AO on the display indicates that the cuff is perfectly placed If the icon AO A appears the cuff is fitted subop timally but it is still ok to measure 3 The cuff will now pump up automatically Relax do not move and do not tense your arm muscles until the measurement ...

Page 6: ...tically stores the last 30 measurement values Viewing the stored values Press the M button 3 briefly when the device is switched off The display first shows M AK and A which stands for the average of all stored values Pressing the M button again displays the previous value Pressing the M button repeatedly enables you to move from one stored value to another Blood pressure readings with suboptimal ...

Page 7: ...replacement batteries Flat battery replacement When the batteries are flat the battery symbol AQ will flash as soon as the device is switched on flat battery displayed You cannot take any further measurements and must replace the batteries 1 Open the battery compartment 5 by pulling off the cap 2 Replace the batteries ensure correct polarity as shown by the symbols in the compartment 3 To set date...

Page 8: ...scription Potential cause and remedy ERR 1 AN Signal too weak The pulse signals on the cuff are too weak Re position the cuff and repeat the measurement ERR 2 AO Error signal During the measurement error signals were detected by the cuff caused for instance by movement or muscle tension Repeat the measurement keeping your arm still ERR 3 AO No pressure in the cuff An adequate pressure cannot be ge...

Page 9: ...d Read the additional safety information provided within the indi vidual sections of this instruction manual The measurement results given by this device is not a diagnosis It is not replacing the need for the consultation of a physician especially if not matching the patient s symptoms Do not rely on the measurement result only always consider other potentially occurring symptoms and the patient ...

Page 10: ...12 g including batteries Dimensions 81 x 65 x 21 mm Cuff size 13 5 23 cm 5 25 9 05 inches Measuring procedure oscillometric corresponding to Korotkoff method Phase I systolic Phase V diastolic Measurement range 20 280 mmHg blood pressure 40 199 beats per minute pulse Cuff pressure display range Resolution Static accuracy Pulse accuracy Voltage source Battery lifetime IP Class Reference to standard...

Reviews: