4. MOUNTING AND INSTALLATION   
 

Caution:

 For added protection, mount the fixtures in areas outside walking paths, seating areas, or in areas were the fixture might 

be reached by unauthorized personnel. Before mounting the fixture to any surface, make sure that the installation area can hold a 
minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment, 
such as an appropriate safety cable. Never stand directly below the device when mounting, removing, or servicing the fixture. 

Whether installing inverted on a truss or ceiling, or set on a flat level surface (see illustration below). Be sure this fixture is kept at 
least 0.5m (1.5 ft) away from any flammable materials (decoration etc.). Always use and install the supplied safety cable as a safety 
measure to prevent accidental damage and/or injury in the event the clamp fails. 

Mounting Points:

 Overhead mounting requires extensive experience, including calculating working load limits. A knowledge of the 

installation material being used, and periodic safety inspection of all installation material and the fixture are all imperative and should 
only be performed by a qualified technician. Improper installation can result in bodily injury and damage. 

Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet. 

Floor Mounting:

 Set the 2 brackets at your desired angle and aim your fixture accordingly. Please see diagram below. 

 

Clamp Mounting:

 The MICROH LEDPRO64RGBW provides a unique mounting bracket assembly that integrates 2 brackets to be 

used to mount on a truss or the floor. When mounting this fixture to truss, be sure to secure an appropriately rated clamp to the 
included bracket fitted through the center hole. As an added safety measure, be sure to attach at least one properly rated safety 
cable to the fixture. 

 

Regardless of the rigging option you choose for your MICROH LEDPRO64RGBW wash fixture, always be sure to secure your 
fixture with a safety cable. The fixture provides a built-in rigging point for a safety cable on the hanging bracket as illustrated above. 
Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle. 

 

Summary of Contents for LEDPRO64RGBW

Page 1: ......

Page 2: ...ctly following CE standards complying with international standard DMX512 protocol This fixture is applicable but not limited to large scale live performances theater studio nightclubs and discos The M...

Page 3: ...low If your fixture is or has become damaged in any way it shall be exclusively replaced or repaired by the manufacturer to avoid any hazard 3 OPERATION INSTRUCTIONS Do not turn on the fixture if it h...

Page 4: ...peed from 1 99 From slow to quick 15 COLOUR CHANGE Press MODE button select J Press UP or DOWN to select the colour change speed from 1 99 From slow to quick 4 COLOUR FADE Press MODE button select F P...

Page 5: ...ing used and periodic safety inspection of all installation material and the fixture are all imperative and should only be performed by a qualified technician Improper installation can result in bodil...

Page 6: ...es together as referred in the diagram below Always end your DMX 512 connection with a DMX terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy en...

Page 7: ...NNELS CH NO VALUE FUNCTION CH1 000 189 Brightness Adjust dim bright 190 250 Strobe slow fast 251 255 No function CH2 000 255 Red dim bright CH3 000 255 Green dim bright CH4 000 255 Blue dim bright CH5...

Page 8: ...igital Display MODE UP DOWN 9 TECHNICAL SPECIFICATIONS MODEL LEDPRO64RGBW LAMP 36 x 3W LEDs 9 Red 9 Green 9 Blue 9 White OPERATING TEMPERATURE 25 C to 45 C VOLTAGE 120VAC 60Hz 1 1A 132W FUSE 120VAC 2A...

Page 9: ...accumulation of dust dirt etc 2 Clean the fan each week 3 A detailed electrical check by approved technician every three months is advised Ensure the circuit contacts are in good condition and preven...