PLEASE NOTE:
All information for this product is subject to change without notice!
Problem and Solution
Problem
Reason
Resolution
Device not functioning
No power
AC 120V, 60Hz
Check the power connection,
and make sure device connect
the mains Device not work No
power in well condition. Check
if switch is on Check if the fuse
is good
LED Bulb is off
LED bulb damage
Replace LED bulb
LED driver board damage
Replace LED driver board
Temperature switch damage Replace temperature switch
Fans not functioning
Fan damage
Replace fans
Cleaning and Maintenance
CAUTION!
Take care using this equipment! High voltage risk of electric shock!
Disconnect from main power before starting maintenance operation!
The cleaning of internal and external optical lenses and/or mirrors must be
carried out periodically to optimize light output. Cleaning frequency depends on
the environment in which the fixture operates: damp, smoky or particularly dirty
surrounding can cause greater accumulation of dirt on the unit’s optics.
1.
Clean with soft cloth using normal glass cleaning fluid.
2.
Always dry the parts carefully.
3.
Clean the external optics at least every 20 days. Clean the internal optics at
least every 30/60 days.