background image

TM

620-0006 R1 © Micro

fl

 ex 2009

General Description

Pulse Scope is a USB oscilloscope designed to aid fi eld service technicians and 

engineers with troubleshooting pulse or frequency related equipment. Use Pulse 

Scope to test PLC digital inputs and outputs, fl ow meters with pulsed outputs, 

speed sensors, and more. Pulse Scope’s simplicity and portability allows you 

to quickly visualize and measure waveform features.  Actually seeing the 

waveform can help locate possible voltage level or pulse width issues making 

your system more reliable. 

• 

Can be set to wait and capture a single pulse event with long delays    

 

 

between events (Single Sweep)

• 

Quickly measure max voltage, minimum voltage, peak-peak voltage, positive  

 

 

width, negative width, period, frequency, and duty cycle 

• 

Count pulse events over extended time periods with a maximum count of 

 

over 4 billion pulses

• 

Trigger on rising or falling pulse edge to increase measurement accuracy

101-0012

Pulse Scope

Field Tools

Installation

Operation &

Specifications

Manual

Summary of Contents for Pulse Scope

Page 1: ...orm features Actually seeing the waveform can help locate possible voltage level or pulse width issues making your system more reliable Can be set to wait and capture a single pulse event with long delays between events Single Sweep Quickly measure max voltage minimum voltage peak peak voltage positive width negative width period frequency and duty cycle Count pulse events over extended time perio...

Page 2: ...aken from the USB port and no external power source is necessary Software Requirements Windows 7 Vista or XP Windows NET Framework 2 3MB Disk Space USB 2 0 Port CD DVD Drive to install the software Running the Software With Pulse Scope connected to a USB port run the software by either clicking on the Pulse Scope icon on your desktop or by choosing it from Start All Programs Microflex Pulse Scope ...

Page 3: ...pulse is driving will see a low logic level The actual value is set using the Setup Trigger menu or by pressing F4 See the Trigger Settings section in this manual for details The pulse scope internal trigger voltage level Input voltages must cross this voltage before the measured pulse edge can be synchronized Also the pulse count item 6 will increment as the pulse edge crosses the trigger voltage...

Page 4: ...e Scope will not start acquiring data until a trigger edge is detected Normal is best when there is a long delay between pulse edges because the Pulse Scope will wait for the pulse event before acquiring the frame Normal Single Sweep Acquire Single sweep is only available when normal is selected It functions the same as normal but stops acquiring after one sweep To acquire a frame press the run bu...

Page 5: ...s the trigger levels used by your digital or pulse input If High and Low are set to the same voltage the red line will be drawn over the green line and only red will be visible If these values are unknown choose a voltage that is approximately between the maximum and minimum measured voltages Vmax and Vmin The Pulse Scope Internal Trigger level is automatically selected to be between the High and ...

Page 6: ... the pulse is synced and at least two pulses are visible Sample Rate Errors Pulse Scope builds a visual representation of the measured waveform by taking voltage readings of the input signal at evenly spaced sample intervals 100 samples per frame The sample interval depends on the time scale If the sample interval is too slow it is possible for the Pulse Scope to provide a waveform that is not rep...

Page 7: ...edance 500KΩ Volt Scales 5V 10V 15V 20V 25V 30V Time Scales 7 Time Scale Sample Interval Frame Width 1 10uS 1mS 2 25uS 2 5mS 3 50uS 5mS 4 100uS 10mS 5 250uS 25mS 6 500uS 50mS 7 1mS 100mS 8 2 5mS 250mS 9 5mS 500mS 10 10mS 1S Pulse Counter Maximum Count 4 2 billion Pulse Count Rate 0 to 100K pulses per second Enclosure Molded ABS Plastic Weight including USB cable 5 ounces Pulse Scope Dimensions 1 3...

Page 8: ...ES NO WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE CUSTOMER S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF MICROFLEX LLC SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER MICROFLEX LLC WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA PROFITS USE OF PRODUCTS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILIT...