4.2.3
Overflow Status Panel
The Overflow Status section, shown in
, represents the three bits in the
Overflow Status Register 1Ch. When an indicator turns red, it indicates an overflow.
FIGURE 4-9:
Overflow Status.
4.2.4
Rsense Panel
The Rsense section, shown in
, needs to reflect the value of the R
SENSE
resistor in use on the evaluation board. This value is used in calculations done by the
GUI. In Demo mode, select the
1 Ohm - Demo
button. In Sys mode, select the
0.005 Ohm - System
button. If another resistor is used, check the
Custom
option
button and fill the corresponding value in the spin box underneath the option.
FIGURE 4-10:
Rsense Configuration Panel.
4.2.5
Panel and Integration Control Panel
The Panel and Integration Control section, shown in
, contains GUI controls
which set and clear the INT_EN bit. When using these controls, check the “READ/INT
OVR” box in the Main Configuration section to allow the INT_EN bit to override the
READ/INT pin state.
FIGURE 4-11:
Panel and Integration Control.
Note:
Read Period (ms) is always enabled.
“READ/INT OVR” Box is Checked