PV Booster Wiring 

– 2 x PV Panels & 2 X PV Boosters 

6

 

7. 

PV Booster Wiring 

– 2 x PV Panels & 2 X PV Boosters 

Panel Input 37V 

– Booster Output 350V  

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 310V

Page 1: ...PV BOOSTER 310 350 550V User Manual Manual Version PVB 2017 2...

Page 2: ...View 3 3 2 PV Booster Side View 3 4 PV Booster Sizing Criteria 4 5 PV Booster Installation 4 6 PV Booster Wiring 1 x PV Panel 1 X PV Booster 5 7 PV Booster Wiring 2 x PV Panels 2 X PV Boosters 6 8 PV...

Page 3: ...al 800 Volt DC This unit is not a consumer product and should only be handled by qualified electricians Always ground the device to avoid electric shock A grounding wire connection is provided The inh...

Page 4: ...are not currently economical The Solar Voltage Booster is specifically designed for standard 300W 250W to 350W with a Maximum Power voltage VMP of 35V to 40V Only PV Panels with an open circuit volta...

Page 5: ...oster Side View 3 2 No Description 1 Earth Connection 2 Solar Panel Negative Input 3 Solar Panel Positive Input 4 Panel LED 5 High Voltage LED 6 High Voltage Input Negative 7 High Voltage Input Postit...

Page 6: ...ut Voltage 12V and 40V Panel Power Max 360W panel per PV booster Panel Voltage Input 310V Model Booster Approximate Output Voltage DC 350V Model Booster Approximate Output Voltage 550V Model Booster A...

Page 7: ...PV Booster Wiring 1 x PV Panel 1 X PV Booster 5 6 PV Booster Wiring 1 x PV Panel 1 X PV Booster Panel Input 37V Booster Output 350V...

Page 8: ...PV Booster Wiring 2 x PV Panels 2 X PV Boosters 6 7 PV Booster Wiring 2 x PV Panels 2 X PV Boosters Panel Input 37V Booster Output 350V...

Page 9: ...PV Booster Wiring 3 x PV Panels 3 X PV Boosters 7 8 PV Booster Wiring 3 x PV Panels 3 X PV Boosters Panel Input 37V Booster Output 350V...

Page 10: ...age at 37V input 350V 350V 550V Voltage multiplication factor 8 3 9 4 14 9 Rated Output Power 360W 360W 360W Efficiency 95 over wide range 95 over wide range 95 over wide range Ambient Temp Range 40 C...

Page 11: ...lacements are our sole remedies Destrier Electronics shall not be liable for damages whether direct incidental special or consequential even caused by negligence or fault Destrier Electronics owns all...

Page 12: ...E mail Address Details of Product Owner Name Surname Address City Province Contact Number E mail Address Date Installed Microcare 1st Floor Neave Industrial Park Korsten Port Elizabeth P O Box 7227 Ne...

Reviews: