Concentration matrices, names, ranges, units, and derived variable
(continued)
Table E-2:
Process fluid
Matrix file name
Default ma-
trix name
Concentra-
tion range
Tempera-
ture range
Density
unit
Tem-
pera-
ture
unit
Derived var-
iable
HCl 0–32% 0–
49C.xml
HCl
0–32%
0–49 °C
g/cm
³
°C
Concentration
(Density)
Methanol
Methanol 35–60%
0–40C.xml
Methanol
35–60%
0–40 °C
g/cm
³
°C
Concentration
(Density)
Ethylene glycol
Ethylene Glycol
10–50% –20 –
40C.xml
Eth. Glycol
10–50%
−
20 – +40 °C g/cm
³
°C
Concentration
(Density)
E.3
Derived variables and calculated process
variables
The concentration measurement application calculates a different set of process variables
from each derived variable. The process variables are then available for viewing or
reporting.
Derived variables and calculated process variables
Table E-3:
Derived Variable
Description
Calculated process variables
Density at
reference
tempera-
ture
Standard
volume
flow rate
Specific
gravity
Concen-
tration
Net mass
flow rate
Net vol-
ume flow
rate
Density at Refer-
ence
Mass/unit volume, cor-
rected to a given refer-
ence temperature
✓
✓
Specific Gravity
The ratio of the density
of a process fluid at a
given temperature to
the density of water at
a given temperature.
The two given temper-
ature conditions do not
need to be the same.
✓
✓
✓
Mass Concentration
(Density)
The percent mass of
solute or of material in
suspension in the total
solution, derived from
reference density
✓
✓
✓
✓
Concentration measurement matrices, derived variables, and process variables
210
Micro Motion
®
Compact Density Meters (CDM)
Summary of Contents for CDM100M
Page 8: ...Getting Started 2 Micro Motion Compact Density Meters CDM ...
Page 12: ...Before you begin 6 Micro Motion Compact Density Meters CDM ...
Page 20: ...Configuration and commissioning 14 Micro Motion Compact Density Meters CDM ...
Page 26: ...Introduction to configuration and commissioning 20 Micro Motion Compact Density Meters CDM ...
Page 110: ...Integrate the meter with the control system 104 Micro Motion Compact Density Meters CDM ...
Page 116: ...Operations maintenance and troubleshooting 110 Micro Motion Compact Density Meters CDM ...
Page 124: ...Transmitter operation 118 Micro Motion Compact Density Meters CDM ...
Page 194: ...Using the transmitter display 188 Micro Motion Compact Density Meters CDM ...
Page 208: ...Using ProLink III with the transmitter 202 Micro Motion Compact Density Meters CDM ...