1. GENERAL INFORMATION  ......................................................................................................... 3
 

1.1 TERMS USED ...................................................................................................................... 3

 

1.2 LIMITATION OF LIABILITY ............................................................................................... 3

 

1.3 COPYRIGHT PROTECTION ............................................................................................... 3

 

1.4 CUSTOMER SERVICE ........................................................................................................ 3

2. INSTALLATION ........................................................................................................................ 4-5

3. CALIBRATING ............................................................................................................................. 5 
 
4. CONNECTION EXAMPLES ..................................................................................................... 6-7
 

4.1  BASIC SETUP USING NITROGEN GAS CYLINDER AND CONNECTING 

ONE PRODUCT TO BOTH A STILL AND NITRO FAUCET

 

4.2 BASIC SETUP USING NITROGEN GAS CYLINDER & BEVERAGE PUMP 

 
5. TROUBLESHOOTING .................................................................................................................. 8

6. ROUTINE MAINTENANCE & CLEANING.................................................................................. 9

TABLE OF 

CONTENTS

|   2

INLINE MININIM™ USER MANUAL AND INSTALLATION GUIDE  

Summary of Contents for INLINE MININIM

Page 1: ...COMPLETELY Before getting started please read this user manual and at all times follow the important safety instructions USER MANUAL INSTALLATION GUIDE FOR NITROGEN INFUSED BEVERAGES For installation...

Page 2: ...ON 4 5 3 CALIBRATING 5 4 CONNECTION EXAMPLES 6 7 4 1 BASIC SETUP USING NITROGEN GAS CYLINDER AND CONNECTING ONE PRODUCT TO BOTH A STILL AND NITRO FAUCET 4 2 BASIC SETUP USING NITROGEN GAS CYLINDER BEV...

Page 3: ...Technical modifications by the user Use of non approved spare parts 1 3 INTELLECTUAL PROPERTY AND COPYRIGHT PROTECTION All rights reserved Any including but not limited to duplication dissemination an...

Page 4: ...NIM this will result in a non functioning MiniNIM Connect the dispensing line to the 3 8 O D liquid outlet barb using the appropriate clamp Connect gas line to 3 8 O D inlet and secure with appropriat...

Page 5: ...r a period of days 4 Gas pressure will be from 10 to 20 lbs depending on the liquid pressure setting NOTE The perfect pour is subjective As a general rule there should be little or almost no bubbles o...

Page 6: ...ONNECTING ONE PRODUCT TO BOTH A STILL AND NITRO FAUCET PRODUCT IN 30 40 PSI STILL PRODUCT FAUCET INFUSED PRODUCT FAUCET FLOW DIRECTION GAS IN APPROX 17 PSI OF N FOR 30 PSI LIQUID PRESSURE MININIML161...

Page 7: ...UMP STOUT FAUCET PRE MIXED PRODUCT NOT PRESSURIZED FLOJET PUMP MININIML161 GAS IN APPROX 17 PSI OF N FOR 30 PSI LIQUID PRESSURE 10 20 PSI OF NITROGEN PRESSURE SET REGULATOR STARTING PRESSURE TO 30 PSI...

Page 8: ...egulator sullying gas to the MiniNIM PRODUCT DOES NOT FLOW FROM THE FAUCET Kinked blocked or damaged hose Check the liquid in and liquid out hoses for kinks or flat spots Re route or replace hoses as...

Page 9: ...te cooler multiply length of run x 1 oz per foot to determine amount of chemical needed 8 Place an empty bucket under the faucet 9 Re connect keg coupler and pressurize container Open the faucet until...

Page 10: ...MORE INFORMATION TROUBLESHOOTING OR SERVICE PLEASE CALL SUPPORT AT 866 327 4159 02214 D1120 2020 Micro Matic USA Inc All Rights Reserved Micro Matic reserves the right to change specifications without...