2.2.3 Access Control
➢
64 Time set
,
64 Time zone
,
32 Group
,
50 Holiday configurable.
➢
Applicable for lift control system.
➢
Configurable door lock release time, exit button, and APB (BF-20 relay and Wiegand reader should apply),
Door open and delay time.
2.2.4 Access Log
➢
Web based real time access log look up function applicable for user account.
➢
Access log look up method can be combined User ID, Terminal ID, Department, Function keys, Time Zone.
➢
Web based First In/Last Out access log look up for user account.
➢
Web based access log report extraction (TXT and XLS).
➢
Software based log extraction.
2.2.5 Verification mode
➢
MF61 series provide 6 verification mode for user account, including 1.Fingerprint 2.RFID Card 3.Password
4.Fingerprint and Password 5.Fingerprint or Password 6.Fingerprint and Mifare card – for Mifare Terminal
only)
➢
Provide Group, Time Zone, Fingerprint and Password, RFID Card and Password time zone for advance
security verification option.