Page 1: ...WDS 40 MT19 P WDS 80 MT33 P WDS 130 MT56 P Operating Instructions wireSENSOR WDS Series...

Page 2: ...ealth and safety requirements of the EC Machinery Directive including modifications to it applicable at the time of this declaration based on its design and construction and in the version put on the...

Page 3: ...ns and performance criteria for transducers with integrated or remote signal conditioning Directive 2011 65 EU RoHS EN 50581 2012 Technical documentation for the assessment of electrical and electroni...

Page 4: ...wireSENSOR WDS series...

Page 5: ...ing Principle 10 2 2 Structure 10 2 3 Technical Data 11 3 Delivery 12 3 1 Unpacking Included in Delivery 12 3 2 Storage 12 4 Installation and Assembly 13 4 1 Precautions 13 4 2 Sensor Mounting 14 4 3...

Page 6: ...wireSENSOR WDS series Appendix A 1 Accessories 23 A 1 1 Wire Extension 24 A 1 2 Mounting Bracket Set 25...

Page 7: ...p for users 1 2 Warnings Do not open the sensor housing Risk of injury due to pre tensioned spring motor Do not let the measuring wire snap Risk of injury due to whiplash of the wire with mounting bol...

Page 8: ...f Conformity is not issued according to EMC law and the Machinery Directive 1 4 Intended Use Draw wire displacement sensors are used for test applications during crash tests for simulators and in test...

Page 9: ...out the measuring wire beyond the measuring range listed This causes the wire to break and thus uncontrolled snapping of the measuring wire Risk of injury Do not have sensor held by a second person w...

Page 10: ...y flexible stainless steel cores is wound onto a drum by using a durable spring motor The winding drum is coupled axially with a potentiometer made of conductive plastic Fig 1 Draw wire displacement s...

Page 11: ...g wire Stainless steel Wire mounting Eyelet 4 5 mm Installation Through holes 2 1 mm Through holes 3 2 mm Through holes 4 2 mm Temperature range Operation 40 to 85 C 40 185 F Storage 40 to 85 C 40 185...

Page 12: ...there is damage or parts are missing immediately contact the manufacturer or your supplier i The transport lock of the measuring wire must only be removed immediately prior to installation and only b...

Page 13: ...asuring wire Do not kink the measuring wire Do not pull the measuring wire diagonally Do not let the measuring wire drag around objects Attach the measuring wire to the measured object while the wire...

Page 14: ...ed in a special way Select the installation position in such a way that damage to or contamination of the measuring wire is avoided i If possible prefer an installation position in which the measuring...

Page 15: ...stallation of fastening bracket Fig 4 Installation with the wire outlet at an infinitely variable angle complete set see Chap A 1 2 i Combined installation is only possible for sensors WDS 80 MT33 P a...

Page 16: ...reSENSOR WDS series 4 3 Dimensional Drawings 8 31 15 59 19 75 8 1 32 2 9 5 37 15 59 19 75 29 7 1 17 4 5 18 dia 2 x 2 1 7 5 d i a m o u n t i n g h o l e 4 8 19 8 3 1 Fig 5 Dimensional drawing WDS 40 M...

Page 17: ...WDS series 2 x 3 2 13 dia 14 25 56 4 5 18 dia 8 3 1 d i a 43 7 1 72 33 1 3 27 1 06 m ounting hole 33 1 3 27 1 06 19 75 2 08 5 4 21 2 9 8 39 8 x M2 5 depth 5 mm mounting hole Fig 6 Dimensional drawing...

Page 18: ...eries 8 x M3 depth 6 mm mounting hole 2 x 4 2 1 7 m o u n t i n g h o l e 4 5 18 dia 14 2 56 66 7 2 63 48 1 89 56 2 2 48 1 89 56 2 2 34 1 34 11 9 47 3 8 15 6 2 24 2 08 8 3 1 d i a Fig 7 Dimensional dr...

Page 19: ...ct Correct Attach the measuring wire to the measured object by using a wire eye Guide the measuring wire vertically out of the sen sor housing Diagonal pull is only permitted up to 3 degrees If you dr...

Page 20: ...w Red Fig 9 Table of potentiometer output Draw wire displacement sensors with potentiometer output are connected according to the table see Fig 9 Use any potentiometer only when switched to voltage di...

Page 21: ...ur dealer must be notified immediately The liability for material defects is 12 months from delivery Within this period defective parts except for wearing parts will be repaired or replaced free of ch...

Page 22: ...he packaging materials in compli ance with the applicable country specific waste treatment and disposal regulations of the region of use 9 Service Repair In the event of a defect in the sensor please...

Page 23: ...10 000 mm WDS MB19 Mounting bracket set WDS MB19 Mounting bracket for sensor WDS 40 MT19 P incl screws for sensor fastening WDS MB33 Mounting bracket set WDS MB33 Mounting bracket for sensor WDS 80 MT...

Page 24: ...series A 1 1 Wire Extension 9 5 37 1 04 9 35 Ring thickness 2 mm 51 18 71 3 dia 0 12 xxxx mm 1 10 mm Min length 120 4 72 0 45 dia 0 02 40 1 57 25 98 7 5 dia 0 30 4 dia 0 16 Fig 10 Wire extension WE xx...

Page 25: ...The mounting bracket set provides you with various installation options see Fig 11 see Fig 12 see Fig 15 Through holes 2 screws for through holes Fastening bracket Screw for installation of fastening...

Page 26: ...zontal installation with the wire outlet at an infinitely variable angle i If the device is installed with the wire outlet at an infinitely variable angle mounting the sensor with only one screw and t...

Page 27: ...f Fastening Bracket WDS MB19 WDS MB33 WDS MB56 A height 33 53 86 B width 26 46 78 D width of foot 10 15 15 E depth of foot 11 11 8 11 8 F hole dimension in foot 4 5 4 5 4 5 G thread size of fastening...

Page 28: ...s depending on sensor type 1 04 B A Dimensions of Sensor Bracket WDS MB19 WDS MB33 WDS MB56 A Outer 30 46 78 B Pitch circle 24 38 2 67 9 C of through hole 2 1 3 2 3 5 Fig 14 Dimensional drawing of mou...

Page 29: ...rew for installation of fastening bracket Fig 15 Vertical installation with the wire outlet at an infinitely variable angle complete set see Chap A 1 2 i Combined installation is only possible for sen...

Page 30: ...Page 30 Service Repair wireSENSOR WDS series 14 3 56 57 2 2 25 46 1 81 14 55 61 2 2 41 Fig 16 Dimensional drawing of WDS MB33 mounting bracket set side view dimensions in mm not to scale...

Page 31: ...Page 31 Service Repair wireSENSOR WDS series 85 7 3 37 24 2 95 86 3 39 18 71 78 3 07 Fig 17 Dimensional drawing of WDS MB56 mounting bracket set side view dimensions in mm not to scale...

Page 32: ...ON MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon de X9751401 A011049HDR X9751401 A01 MICRO EPSILON...