Page 19
Installation and Assembly
wireSENSOR, WPS MK60-M / MK88-M
4.4
Wire Guide and Fastening
If the measuring wire has to be extracted from the sensor to
guide the wire or to fix it to the target,
- the sensor may not be held by another person
- the measuring wire may not be further extracted but only
to the specified measuring range
- the surroundings of the sensor have to be protected
against snapping of the measuring wire
Wrong
Correct
Fix the measuring wire to the target using an wire clip.
Guide the measuring wire vertically out of the sensor
housing.
Misalignment is only permissible up to 3 degrees.
Dragging of the measuring wire on the inlet hole or other
objects leads to damage and/or breakage of the measuring
wire.
i
If the measuring wire cannot be fed vertically out of the
housing, it is essential to use a guide pulley (accesso-
ry TR1-WDS or TR3-WDS), see Chapter Accessories.
Keep measuring wire in an area where it cannot be
snagged or otherwise be violated.
Fig. 6 Wire fastening and misalignment
max. 3 °
Wire outlet 0 °
±3 ° tolerance
A measuring wire under
tension where opera-
tors are standing can
lead to injuries.
> Risk of damage to
wire and sensor.
Do not twist the measu-
ring wire!