background image

DS05(03)
DS05(04)
DS05(07)
DS05(14)
DS05(15)

DS1
DS1(04)
DS1/T

Operating Instructions

turbo

SPEED

 DZ140

Summary of Contents for turboSPEED DZ140

Page 1: ...DS05 03 DS05 04 DS05 07 DS05 14 DS05 15 DS1 DS1 04 DS1 T Operating Instructions turboSPEED DZ140...

Page 2: ...ILON MESSTECHNIK GmbH Co KG K nigbacher Strasse 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon de www micro epsilon com Speed measuring system for turbo...

Page 3: ...ns 8 2 2 Functional Principle 8 2 3 Structure of the Complete Measuring System 8 2 4 Technical Data 9 3 Delivery 11 3 1 Unpacking Included in Delivery 11 3 2 Storage 11 4 Installation 12 4 1 Sensor 12...

Page 4: ...2 Closed Compressor Housing 24 5 4 Test Signal 25 5 5 Settings 26 5 5 1 Mode Turbo Charger Speed Sensitivity Test Signal 26 5 5 2 Number of Blades 27 5 6 Analog Output 28 6 Troubleshooting 29 7 Liabi...

Page 5: ...tes a tip for users Measure Indicates hardware or a software button menu 1 2 Warnings Connect the power supply and the display output device according to the safety regulations for electrical equipmen...

Page 6: ...K nigbacher Str 15 94496 Ortenburg Germany The measuring system is designed for use in industrial environments and meets the requirements 1 4 Intended Use The system is designed for use in industrial...

Page 7: ...el DS1 T 40 235 C 40 455 F short term 285 C 545 F Sensor cable 40 200 C 40 392 F Controller 40 125 C 40 257 F at max 15 VDC power supply 1 Storage temperature Sensor sensor cable 40 200 C 40 392 F Con...

Page 8: ...passing by The eddy current loss principle effects impedance changes in a measuring coil sensor This change of impedance gives rise to an electric signal 2 3 Structure of the Complete Measuring System...

Page 9: ...5 m 0 8 m 0 15 m Number of blades rotary switch accessible from the outside for 1 up to 16 blades Digital output 1 pulse blade switch Blades on 1 TTL level variable pulse duration or 1 pulse revolutio...

Page 10: ...5 15 DS1 DS1 04 DS1 T Storage tem perature Sensor sensor cable 40 200 C 40 392 F Controller 40 125 C 40 257 F Cable PC140 3 supply and output cable 3 m PC140 6 supply and output cable 6 m PC140 8 supp...

Page 11: ...Carefully remove the components of the measuring system from the packaging and ensure that the goods are forwarded in such a way that no damage can occur Check the delivery for completeness and shippi...

Page 12: ...0 12 dia WS4 a p p r 9 5 0 3 7 Sensor cable approx 3 5 mm Length 0 5 m 0 15 m with BNC connector Fig 2 Dimensional drawing DS05 03 66 2 60 3 0 12 dia WS4 appr 9 5 0 37 Sensor cable approx 3 5 mm Leng...

Page 13: ...ngth 0 5 m 0 15 m with BNC connector Fig 4 Dimensional drawing DS05 07 M5 28 1 10 appr 9 5 0 37 WS4 Sensor cable approx 3 5 mm Length 0 5 m 0 15 m with BNC connector Fig 5 Dimensional drawing DS05 14...

Page 14: ...mm Kabell nge 0 8 m 0 15 m with triax BNC connector approx 19 75 Sensor cable with 2 shields triax cable approx 5 mm Length 0 8 m 0 15 m with triax cable socket Fig 8 Dimensional drawing DS1 T M5x0 5...

Page 15: ...ter in the case of dynamic application 5 x diameter in the case of static application Make sure that the plug connectors at the sensor and at the controller fit tightly i As the capacity and the adjus...

Page 16: ...140 is installed in an aluminum housing The controller demodulates and amplifies the speed dependent measuring signal 62 2 44 33 3 1 31 41 3 1 63 83 8 3 3 19 5 0 77 18 0 71 12 3 4 5 6 7 8 9 10 1 1 12...

Page 17: ...do not connect 7 Supply SUPPLY white 8 Power supply 9 30 VDC SUPPLY brown Fig 12 Pin assignment female connector SUPPLY OUTPUT and PC140 x The connector housing electronics housing is connected with t...

Page 18: ...RO EPSILON recommends the power supply unit PS2020 see Chap A 1 12 V on board power supply is possible PS2020 230 VAC PE N L PS2020 PC140 x turboSPEED Remote SUPPLY OUTPUT Mode RAW SIGNAL Blades 12 3...

Page 19: ...e pole of the power supply e g due to connected measuring instruments avoid connecting the controller to loads with high currents e g starter S R Wire I Last U R Wire upply Supply GND BNC DZ140 Contro...

Page 20: ...gn the sensor see Fig 20 see Chap 5 3 2 Load resistance 5 kOhm Disconnect the connected measuring devices after alignment of the sensor distance and close the female connector with the delivered prote...

Page 21: ...Page 21 Installation turboSPEED DZ140 Supply Supply GND Shield BNC Triax DZ140 Controller PE PE PE L PE Sensor GND Fig 18 Ground concept for DSx T sensors...

Page 22: ...ave a very user friendly locking mechanism If the connector is plugged into the device the lock claws on the con nector in device snap and form a reliable connection between the two parts Disconnectio...

Page 23: ...en Initialization turboSPEED Remote Status SENSOR SUPPLY OUTPUT Mode RAW SIGNAL Blades 12 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1516 red No sensor red flashes 1 sec Takt Teach to sensor red flashes quickly...

Page 24: ...pressor Housing With the help of the light emitting diode Status on the controller the sensor can be positioned roughly Connect the signal TTL impulse pin 3 female connector supply output to an oscill...

Page 25: ...Set the switch Mode to 8 The LED Status flares green turboSPEED Remote Status SENSOR SUPPLY OUTPUT Mode RAW SIGNAL Blades 12 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1516 Fig 19 Settings for the test signal...

Page 26: ...e the turbocharger blades 2 and 3 were reliably de tected at a Med sensitivity setting A Low sensitivity setting guarantees the best immunity to interference Ex factory the controller is delivered wit...

Page 27: ...n see Fig 22 SUPPLY OUTPUT RAW SIGNAL Blades 12 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1516 Fig 22 Rotary switch for the number of blades One pulse per blade with variable duration Impulse duration depends...

Page 28: ...40 5 6 Analog Output Range 0 5 V Linear depends on rotation speed Mode 1 3 5 Mode 0 2 4 0 0 100 000 200 000 rpm 2 5 5 V 0 0 200 000 400 000 rpm 2 5 5 V Fig 23 Analog signal for max 200 000 rpm Fig 24...

Page 29: ...devices e g an oscilloscope in which the signal ground GND is connec ted to the protective earth conductor of the mains socket add a galvanic separation e g by means of an isolating transformer Make s...

Page 30: ...pply supply is al ready connected to the housing ground PE e g in the vehicle via the negative pole of the car bat tery since the signal GND and housing ground PE are connected together by the spring...

Page 31: ...In particular MICRO EPSILON shall not be liable for any consequential special indirect or incidental damage In the inter est of further development MICRO EPSILON reserves the right to make design cha...

Page 32: ...SPEED DZ140 Appendix A 1 Optional Accessories PS2020 Power supply unit for mounting on DIN rail Input 230 VAC Output 24 VDC 2 5 A DD241PC 11 U Digital process display Display of a selected measuring v...

Page 33: ...of Controller for Printing turboSPEED DZ140 A 2 Labels on Rear Side of Controller for Printing i The list of modes see Chap 5 5 1 is fixed as a quick guide on the back side of the turboSPEED DZ140 Fi...

Page 34: ...N MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon com X9751314 A071069HDR X9751314 A07 MICRO EPSILON...

Reviews: