Page 27
Installation and Assembly
optoCONTROL CLS1000
Switching output Q1 properties
Sensor
pin
PC1000-x
cable color
Comments
V
+
max 12...30 V DC,
I
max
= 100 mA, signal level depends on supply voltage.
Switching behavior programmable
1
: NPN, PNP, PP
2
White
Switching output Q2
Properties of switching output Q2
V
+
max 12...30 V DC,
I
max
= 100 mA, signal level depends on supply voltage.
Switching behavior programmable
1
: NPN, PNP, PP
4
Black
Switching output Q1
For switching outputs Q1 and Q2
3
Blue
Ground
1) The switching behavior is individually programmable and identical for Q1 and Q2.
4.5.6.3 Trigger Input CLS1000-2Q-xx-T
Only applies for controller CLS1000-2Q-xx-T with trigger function. The trigger input enables recording of measurement
values/output of measurement values with averaging, as well as various trigger types
GND
1
3
2
4
Q1
Q 2
PP / PNP / NPN
PP / PNP / NPN
Trigger
5
V
+
Brown
White
Black
Gray
Blue
Fig. 26 Circuit for CLS1000-2Q-xx-T
Trigger input properties
Sensor
pin
PC1000-x
cable color
Comments
3
Blue
Ground
max. 30 VDC; input current
I
max
= < 1 mA
5
Gray
Trigger (IN)
When wiring the trigger input with an NPN output, an external resistance
≥ 4.7 kΩ ≤ 10 kΩ is necessary.