Page 33
Measure
optoCONTROL 2600
6.3.7.8 Measurement Modes
The ODC 2600-40 measurement system can be operated in various measurement
modes.
Apart from the normal mode, measurements can be held and peak values can be mea-
sured continuously and triggered.
The possible measurement modes are summarized in Table
The selection is made in the operating menu
.
Measurement
mode
Remark
Name in display
Normal
Continuous measurement output-
standard setting
NORMAL
Maximum value,
continuous
Output of the max. value in continu-
ous measurement operation, value
is held until change or reset pulse
occurs. No evaluation of a trigger
pulse.
MAX CONT
Minimum value,
continuous
Output of the min. value in continu-
ous measurement operation, value
is held until change or reset pulse
occurs. No evaluation of a trigger
pulse.
MIN CONT
Peak to peak,
continuous
Output of the P-P value in continu-
ous measurement operation, value
is held until change or reset pulse
occurs. No evaluation of a trigger
pulse.
P-P CONT
Maximum value,
triggered
Output of the max. value found
between two trigger pulses (corre-
sponds to sampling period). The
value is held on the output until the
next trigger pulse or reset pulse.
MAX TRIG
Minimum value,
triggered
Output of the min. value found
between two trigger pulses (corre-
sponds to sampling period). The
value is held on the output until the
next trigger pulse or reset pulse.
MIN TRIG
Peak to peak,
triggered
Output of the P-P value found
between two trigger pulses (corre-
sponds to sampling period). The
value is held on the output until the
next trigger pulse or reset pulse.
P-P TRIG
Momentary value,
triggered
Output of the momentary value
valid at the time of the trigger pulse.
The value is held on the output until
the next trigger pulse or reset pulse.
SC1 TRIG
Fig. 32 Measurement modes of the optoCONTROL 2600-40
Summary of Contents for ODC 2600-40