Mounting

ELTROTEC Panoramascope

4.7 

Light Source

  Insert the optical fiber into the fiber optic connection at the light source, see 

Fig. 13

.

Certain optical fibers (such as gooseneck fiber optics with multiple arms) and adapters are equipped with a 
cam (spin lock) which is kept in place in the ring lock recess to prevent the connected plug from rotating.

Optical fiber

Fiber optic connection

Fig. 13 Connecting the optical fiber with the light 
source

Fig. 14 Connected optical fiber

Summary of Contents for ELTROTEC panoramascope

Page 1: ...Instruction Manual ELTROTEC Panoramascope...

Page 2: ...t and cavity walls MICRO EPSILON Eltrotec GmbH Heinkelstrasse 2 73066 Uhingen Germany Phone 49 0 7161 98872 300 Fax 49 0 7161 98872 303 e mail eltrotec micro epsilon de www micro epsilon com Certified...

Page 3: ...awing for Panoramascope 12 4 2 Installing Lens and Camera 12 4 3 Assembling the Screw Threaded Lens 13 4 4 Assembling the Quick Release Lens 13 4 5 Connecting the USB Camera with the USB Cable 14 4 6...

Page 4: ...ions for Operation 20 7 1 Cleaning 20 7 2 Maintenance 20 8 Warranty 21 9 Service Repair 21 10 Decommissioning Disposal 21 Appendix A 1 Accessories 22 A 1 1 Light Sources 22 A 1 2 Fiber Optic Cables 22...

Page 5: ...a situation which may result in property damage if not avoided Indicates a user action i Indicates a user tip 1 2 Warnings The probe is electrically conductive Avoid contact with live parts Death by e...

Page 6: ...estruction of the endoscope 1 3 Proper Use The ELTROTEC panoramascope is used to monitor and inspect the inside of machines equipment and cavity walls The ELTROTEC panoramascope is not suitable for me...

Page 7: ...C to 50 C 4 F to 122 F Humidity up to 95 at 40 C 104 F non condensing Ambient pressure up to 3 bar The maximum continuous service temperature of the endoscope probe must not exceed 20 C to 70 C 4 F to...

Page 8: ...ce to focus the image The cladding tube of the endoscope consists of corrosion resistant stainless steel which protects the optics against the strain of everyday use The cladding tube of the endoscope...

Page 9: ...system guides the lens generated image through the endoscope cladding tube to the eye piece Field of view approx 90 360 all round view Direction of view 90 Light Panorama lens Fig 2 Direction of view...

Page 10: ...ly 2 mm to infinite Impermeability Device is not liquid tight due to exchangeable panorama lens Illumination Fiber optic connector for external light source Diopter adjustment Yes external focus ring...

Page 11: ...sources optical fibers and cameras are listed in Optional Accessories see Chap A 1 Check the delivery for completeness and shipping damage immediately after unpacking In case of damage or missing par...

Page 12: ...amascope in mm not to scale 11 43 dia 7 2 28 dia 6 7 26 Fig 5 Dimensional drawing for panorama lens in mm not to scale 4 2 Installing Lens and Camera Remove any protective caps from the lens and from...

Page 13: ...ascope 4 4 Assembling the Quick Release Lens The eye cup remains connected to the endoscope Push the quick release fastener back from the lens and slide it over the eye cup see Fig 7 see Fig 8 Camera...

Page 14: ...see Fig 9 USB camera USB cable Fig 9 Connecting the USB camera with the USB cable Fig 10 Final assembly of the endoscope incl USB camera laptop and light source i Tighten the screws to ensure that th...

Page 15: ...power source see Fig 11 Connect the remote control unit to the OSD socket see Fig 11 in order to fine tune the camera settings such as white balance gamma correction and shutter times Remove the cable...

Page 16: ...13 Certain optical fibers such as gooseneck fiber optics with multiple arms and adapters are equipped with a cam spin lock which is kept in place in the ring lock recess to prevent the connected plug...

Page 17: ...Never look directly at the light source or into the optical fiber Risk of blinding damage to the eyes Adjust the light intensity depending on the degree of reflection Turn the knurled ring on the eyep...

Page 18: ...Unscrew the panorama lens counterclockwise from the endoscope Please make sure that no dust or dirt gets into the panoramascope Damage to or destruction of the panoramascope Screw the new panorama le...

Page 19: ...ight be dirty Clean the panorama lens glass or the lens gen tly to remove stains and dirt see Chap 7 1 6 2 2 Scratches and Damages Possible cause Troubleshooting The lens of the eyepiece or the panora...

Page 20: ...essed air or the cleaning set i We recommend using a cotton swab moistened with alcohol to clean the eyepiece fiber optic connector and lens Please use isopropyl alcohol rubbing alcohol If the endosco...

Page 21: ...anted are accepted MICRO EPSILON Eltrotec will specifically not be re sponsible for eventual consequential damages We reserve the right to make design changes in the interest of further development 9...

Page 22: ...ight Sources Description Photo Description Item number Eltrotec Endolight FOT LED High performance LED light source 20912110 A 1 2 Fiber Optic Cables A 1 3 Cameras Description Photo Description Item n...

Page 23: ...Camera parameters can be set via cable remote control external power supply 20961577 Analog color CCD camera Endo CA1 2 20962287 USB 2 0 color camera Endo CU1 3 Includes software for image display an...

Page 24: ...on the following page Example An endoscope with a 2 8 mm diameter is used in conjunction with a USB camera containing a 1 3 camera chip We recommend using a 25 mm lens to get a full size image 1 2 ch...

Page 25: ...up 20961001 Focal length f 18 35 mm suitable for all endoscope types with a 32 mm eye cup 20962209 C mount TV lens fixed focal length 32 mm focal length M14x1 for rigid endoscopes SKF D and MKF D with...

Page 26: ...MICRO EPSILON Eltrotec GmbH Heinkelstr 2 73066 Uhingen Germany Phone 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon de www micro epsilon com X9751373 A011037HDR X9751373 A01...

Reviews: