Page 41
Outputs and Inputs
thermoMETER CT
8.2
Digital Interfaces
All CT sensors can be optionally equipped with an USB-, RS232-, RS485-, Profibus DP-, CAN-Bus-, Modbus
RTU- or Ethernet interface.
In the case that you want to use the delivered cable gland M12x1.5 for the interface cable, please disassem-
ble the terminal block and assemble them again.
To install, first remove the housing cover to get access to the interior of the housing.
Now take the particular interface board and insert it into the slot provided in the controller.
The slot is located on the left side of the display
In the correct position the holes of the interface match with the thread holes of the controller.
Now press the interface board down gently to connect it and use both M3x5 screws for fixing it in the
controller housing.
Plug the pre-assembled interface cable with the terminal block into the male connector of the interface
board.
Fig. 15 Interface board
Exchange the blind screw on the controller by the cable gland of the respective interface and install the
appropriate interface cable.
i
Please also pay attention to the additional notes for installing the respective interfaces