Page 9
Functional Principle, Technical Data
colorCONTROL MFA-7/-14/-21/-28
2.5.2
Technical Data for MFS Sensors
Model
MFS-22
MFS-K04
MFS-K04-3
MFS-K04-6
MFS-K05/90
Article number
10825504
10825506
10825508
10825510
10825512
Sensor type
Receiver sensor
Working
distance
1
Start
3 mm
3 mm
3 mm
3 mm
Optimal
5 mm
5 mm
5 mm
5 mm
End
11 mm
15 mm
15 mm
15 mm
Measurement
spot diame-
ter
1
Start
4 mm
3 mm
4.5 mm
2x5 mm
Optimal
6 mm
3 mm
5 mm
2.5x6 mm
End
16 mm
6 mm
7 mm
4x14 mm
Measurement geometry
0°
90°
Min. target size
Ø 4 mm
Ø 3 mm
Ø 4.5 mm
Ø 5 mm
Sensitivity
Distance
2
xy
< 0.003 /mm
xy
< 0.002 /mm
xy
< 0.003 /mm
xy
< 0.004 /mm
Tilt
2
xy < 0.01 / °
xy < 0.01 / °
xy < 0.02 / °
xy < 0.02 / °
Connection
Integrated plastic fiber cable axial with PVC (P) sheathing,
standard length 0.5 m; other lengths 0.3 m... 2.0 m optionally available,
min. bending radius 50 mm
Mounting
MFS plug
Temperature
range
Sensor head
-10 ... +80 °C
Cables
-20 ... +80 °C
Humidity
20 … 80 % RH (non-condensing)
Protection class (DIN EN
60529)
IP64
IP44
Material
PVC,
plastic fiber
POF-2.2 with
PVC sheathing
(P)
Aluminum,
plastic fiber POF-2.2 with PVC sheathing (P)
Weight
3.4 g
5.4 g
5.6 g
7.2 g
6.7 g
Compatibility
MFA controller (7, 14, 21, 28)
Special features
All variants are available in other lengths > 300 mm as well. Lengths of up to 5 m are
possible with glass optical fibers. These can also be manufactured for vacuum or
high-temperature conditions.
No. of measurement channels
1
Details apply in conjunction with a colorCONTROL MFA-7 series controller
1) Measured with a white reference light source 6500 K, 32 lm, 95 Ra
2) Measured with red 637 nm 5 mm LED (1 mA, 11 V DC)