background image

R60ATR2-Single track module using guide

5

TEL:0755-88602663

[email protected]

www.micradar.cn

501, West Block, Phase II, Tian 'an Innovation Technology Plaza, Futian District, Shenzhen

distance and then stop at any position

actual distance is within the specified
accuracy range, within the specified
accuracy range, it means "pass"

Example test table format:

Testing

frequency

Radar distance

information

Compared with real distance

information

Whether it is within the

accuracy requirements

pass

the first

time

2.1m

Yes

pass

Static angle information accuracy test:

The mobile test is carried out within the radar detection range, and when it stops
at a random position, the last angle reported by the radar is compared with the real
angle to confirm whether the distance error value is within a reasonable range to
confirm the accuracy of the distance information.

carry out testing
Move freely within the range for a certain
distance and then stop at any position

Determine whether the error between the
angle finally reported by the radar and
the real angle is within the specified
accuracy range, and within the specified
accuracy range, it means "pass"

Example test table format:

Testing

frequency

Radar angle
information

Compared with real distance

information

Whether it is within the

accuracy requirements

pass

the first

time

50°

Yes

pass

9. Guide to the actual installation steps of the radar

Step 1: Confirm the main activity and stay area of the person, which is the coverage

area of the radar

Step 2: Confirm the actual horizontal installation height of the radar is 1.2m-1.5m

Step 3: Confirm whether there is an interference source within the radar detection

range , and remove the interference source as much as possible

Step 4: Follow the steps to confirm the final installation location for normal use

10.Layout Requirements for Antenna and Housing

PCBA: Need to keep the height of the radar patch ≥ 1mm than other devices

Summary of Contents for R60ATR2

Page 1: ...Bio sensing radar 60G Milimeter wave MicRadar Technology Shenzhen Co LTD R60ATR2 Single track module using guide Please read the product instructions carefully before use and keep them properly V1 0...

Page 2: ...e personnel through the change of the radar echo in real time the real time reporting of the position of the personnel is realized and the trajectory tracking effect is realized According to the magni...

Page 3: ...iption Radar module structure diagram Pin description Note 1 GP1 GP6 are parameter selection control terminals which can be redefined according to user needs 2 The output signals of this interface are...

Page 4: ...stallation direction and detection range 7 2 1 Horizontal installation To ensure the accuracy of radar detection please install it horizontally The radar is installed horizontally to ensure that the m...

Page 5: ...n normally report the real time angular distance change information of the target every second if the output can be judged normally it means pass Example test table format Testing frequency move Is th...

Page 6: ...rry out testing Move freely within the range for a certain distance and then stop at any position Determine whether the error between the angle finally reported by the radar and the real angle is with...

Page 7: ...positives Usually electric fans pets close to the radar and the shaking of metal curtains can cause false positives Radar needs to be planned in terms of installation angle Non interfering factors rad...

Reviews: