background image

Veri-Q PREP M16

G2-16TU

User Manual

Apr. 2020

Cat No. 9S101

Summary of Contents for 9S101

Page 1: ...Veri Q PREP M16 G2 16TU User Manual Apr 2020 Cat No 9S101...

Page 2: ...16TU For safe use please use the device after reading the manual thoroughly Please furnish this document at a designated location so it can be used at all times MiCo BioMed Co Ltd 3rd and 4th Floor 54...

Page 3: ...3 How to Obtain More Information 6 1 4 About Customer Support 6 1 5 Precautions on distribution or duplication of the manual 6 1 6 Laboratory Biosafety 6 2 Safety Guideline 7 2 1 Precautions when usi...

Page 4: ...pleting a training course Servicing on G2 16TU is performed by MiCo BioMed 2 1 3 The user must use only components of MiCo BioMed in order to receive guarantee of the product Please perform regular ma...

Page 5: ...ppropriate data values 2 1 5 If the device does not meet the performance conditions make an inquiry to the manufacturer 2 1 6 This device is an electronic and mechanical device Since there is a risk o...

Page 6: ...or fumes and disposal of wastes must follow all national and local health and safety regulations and laws Please wash your hands after handling the reagents 2 2 19 Operate the product in an environmen...

Page 7: ...each parts Near sample tubes Biological hazard Since the tubes or waste cartridges become contaminated with biohazardous materials they must be handled while wearing gloves Near buffer bottles and sam...

Page 8: ...tantaneous maximum power consumption 110W Safety device We made sure the electric shock inside the board does notaffect the element by using Varistor on operating parts such as valve pump fan etc We m...

Page 9: ...l be filled in this waste cartridge Lid This lid will cover the Elution Cartridge 3 6 Equipment Part Names and Functions 1 2 3 4 5 6 7 No Name Explanation 1 LCD Operates and sets equipment with touch...

Page 10: ...y Fluid control part for washing air pumping and extraction Moving part to perform pre treatment per channel 4 1 2 Operation Principle This device has the function to rapidly extract nucleic acid from...

Page 11: ...e G2 16TU and then turn on the power 2 When power is supplied to the device POWER LED should light up Please refer to the following photo The green light coming on means the device is working properly...

Page 12: ...place a Pre run Cartridge in an appropriate position of Sample Rotor Do not place the Pre run cartridge upside down The buffer solution can flow into the equipment Please refer to the photo below X O...

Page 13: ...nge menu page by pressing image or pressing button You can check the firmware version on the left corner The latest version is v2 00 4 5 8 Select extraction volume 1 Press E Volume image or button You...

Page 14: ...ration 4 5 9 Start operation 1 Press START button or Start image The equipment automatically operates Please refer to the following for operating procedures A Checking Binding When the user operates t...

Page 15: ...e visit http micobiomed com or send an e mail to salesbio micobiomed com C Elution In this step the eluate will be gathered in the micro tube which is inserted into the elution cartridge Because G2 16...

Page 16: ...ipment b When sample extraction is complete In this case take the following measures a Remove all sample tubes from the upper tray b Press INIT image or SET button Washing1 Buffer Empty This error mes...

Page 17: ...ed purchase information please check the homepage http micobiomed com 7 Warranty Policy MiCoBioMed shall be excluded from warranty obligations when a person other than the dedicated engineer performs...

Page 18: ...of the upper tray And if necessary wipe the hole of the upper tray with a cotton swab 12 2 4 Open even the lower tray and wipe it in the same manner 12 3 Cleaning of Pre run Cartridge 12 3 1 Dispose...

Page 19: ...ound the equipment The device is not exposed to direct sunlight There are no installations that can cause dust heat and fluid inflow into the equipment The port switch direction on the rear of the equ...

Page 20: ...not be required to replace any unit which is damaged or malfunctions due to abuse accidents alteration neglect misuse maintenance by someone other than Mico BioMed co Ltd or failure to operate in acco...

Page 21: ...Veri Q PREP M16 G2 16TU MiCo BioMed Co Ltd 3rd and 4th Floor 54 Changeop ro Sujeong gu Seongnam si Gyeonggi do Korea 13449 TEL 82 70 5227 6000 FAX 82 70 5227 6001 2 User Manual Apr 2020...