Installation using Additional Thread Adaptor
1.
Remove the protective cover and desiccant capsule from the transmitter and retain for future
use
2.
Prevent any contamination of the sensor before installation by handling the transmitter by
the main body only, avoiding contact with the sensor guard.
3.
Pass the bonded seal over the 5/8”- 18 UNF mounting thread.
4.
Screw the transmitter into the adaptor, and tighten to 30.5 Nm (22.5 ft-lbs)
5.
NOTE: Use the flats of the hexagonal nut and not the sensor body.
6.
Screw the transmitter (1) with its seal (3) and adapter (4) into the sampling location block
(and fully tighten using a wrench to the following torque settings:
•
G 1/2” BSP 56 Nm (41.3 ft-lbs)
•
3/4” - 16 UNF 40 Nm (29.5 ft-lbs)