Micha Solar
MSRx Charge Controller
User Operation Manual
Page 30 of 46
Document: 802440-30.doc
Date: December 2020
www.micha.co.uk
Menu E Notes:
Menu E Screen 0-5 – Expansion Port Modules:
For full details of the Expansion Port Modules and the Settings Menu, see Section 6
Menu E Screen 13 – Battery Temperature Charging Function:
Disable Charging on Battery Temperature Function = Off:
No change to charge controller operation
Disable Charging on Battery Temperature Function = On:
If the Battery Temperature is greater than or equal to the High Temperature Parameter (set using Menu
E Screen 13), then Battery Charging will be disabled.
If the Battery Temperature is equal to or less than the Low Temperature Parameter (set using Menu E
Screen 14), then Battery Charging will be enabled.
Menu E Screen 14 – Battery Temperature Charging High Temperature Parameter:
Disable Charging If Battery Temperature is greater than or equal to High Temperature Parameter
Parameter can be adjusted from 1-70°C (default = 60°C)
Menu E Screen 15 – Battery Temperature Charging Low Temperature Parameter:
Enable Charging If Battery Temperature is less than or equal to Low Temperature Parameter
Parameter can be adjusted from 0-69°C (default = 58°C)