ETS2228 Maintenance Manual
All right reserved
Page 28, Total 43
Reference source signal indices:
:
(
1
)
Frequency
19.2MHz
(
2
)
Frequency error
±
2ppm
(
-30
℃~
85
℃)
(
3
)
Output signal amplitude
0.5Vpp
(
min
)
Indices of emitting and receiving intermediate frequency local oscillation signals
:
Zero intermediate frequency method
RF
local oscillation signals Indices
:
(
1
)
Output frequency:
1664
~
1788MHz
;
(
2
)
Output power:
-12dBm
2 .
Electric Indices