background image

2

MIATECH TECHNICAL INSTRUCTIONS   |   BIO TURBO 100 USER GUIdE

SpECIfICATION SHEET  |  JAN 15, 2020

Features

•  LED lights for quick diagnostics
•  Easy service 
•  Easy changing of ozone plates and filters 
•  Four models for proper coverage 
•  Aluminum and Stainless Steel 

generation chamber 

•  Easy to install and operate 
•  Low maintenance 

Model(s)

Bio Turbo 100

Maximum volume up to  

3300 ft³ (100 m³) per 24 hours

Airflow

3 CFM (0 .1 CMM)

Location Requirements
Electrical Source

100-240 VAC

Circuit Breaker

5A

Maintenance
Air Filter

Change every 12 months

Ozone Plate(s)

Change every 12 months

Number of Ozone Plates

1

Specifications
Size: 

Height

4 inches (10 cm)

Width

18 inches (45 cm)

Depth

24 inches (60 cm)

Weight

24 lb (11 kg)

Construction
Materials:
         Unit Cabinet

Aluminum

         Perforated Generator Plate

Stainless Steel

Controls
Remote Control:

N/A
Power Switch

Bio Turbo 100

Specification Sheet

Summary of Contents for BIO TURBO 100

Page 1: ...ECHNICAL INSTRUCTIONS Bio Turbo 100 User Guide Specification Sheet 2 Installation Guide 3 Layout Diagram 4 Maintenance Guide 5 Wiring Diagram 6 Pull Sheet 8 JAN 15 2020 AIRBORNE BACTERIA ETHYLENE REMOVAL ...

Page 2: ...urbo 100 Maximum volume up to 3300 ft 100 m per 24 hours Airflow 3 CFM 0 1 CMM Location Requirements Electrical Source 100 240 VAC Circuit Breaker 5A Maintenance Air Filter Change every 12 months Ozone Plate s Change every 12 months Number of Ozone Plates 1 Specifications Size Height 4 inches 10 cm Width 18 inches 45 cm Depth 24 inches 60 cm Weight 24 lb 11 kg Construction Materials Unit Cabinet A...

Page 3: ...sible Since ethylene is lighter than air it will rise toward the ceiling There are four snap clips on the sides for securing the system to its holding frame that can be easily installed to the ceiling see picture 1 Before drilling inspect the area where the system will be mounted for any obstructions that could be damaged Use the supplied screws to attach the holding frame to the ceiling After the...

Page 4: ...o Turbo 100 User Guide Layout Diagram JAN 15 2020 Bio Turbo 100 Layout Diagram Toll Free in North America 1 800 933 6478 www miatech org USA phone 1 503 659 5680 Fax 1 503 659 2204 November 2010 THE ADVANTAGE COUNTS LAYOUT DIAGRAM v 1 1 ...

Page 5: ...shing NOTE a blunt object should be used to reset so damage won t occur to the timer 1 Power Switch 23132 2 5 A Breaker 23247 3 24 V LED 23291 4 3 LEDs 230 V 23193 115 V 23192 5 Service 24 V LED Red 23292 6 Air Filter 11130 7 Cell Disrupter 11163 8 Generator Plate 11129 9 Door Switch 23233 10 Ozone Transformer 23231 11 BT Service Timer 23267 12 Solid State Relay 23222 13 Fan 24 V DC 10037 14 Alarm...

Page 6: ...6 MIATECH TECHNICAL INSTRUCTIONS Bio Turbo 100 User Guide Wiring Diagram JAN 15 2020 Bio Turbo 100 Wiring Diagram ...

Page 7: ...Notes ...

Page 8: ... support in North America call 1 800 933 6478 If outside North America call to the USA at 1 503 659 5680 Bio Turbo 100 Pull Sheet Pack PART NO PART NAME AMOUNT INSP 24034 14 x 2 1 2 Screw 5 24035 14 Plastic Anchor 5 25070 BT Facility Entrance Label See order for language 1 DATE PULLER CHECKER ...

Reviews: