Product Terminal Identification Drawing 

 

 

AC voltage input (U+)

 

AC voltage input (U-) 

Power supply positive (+E)

DC voltage output (Uz )

 

Power supply and output ground (GND)

 

 

 

 

 
 
 
 

Non Identified Terminals Cannot Used

 

 

Key Technical Data: 

1.

 

Input: AC 0~10V; 0-50V; 0-100V; 0-250V;0-300V; 0-500V; 

2.

 

Output: TRUE RMS 0~5V; or 0-10V (optional) 

3.

 

frequency range: 

50Hz; 60Hz

 

4.

 

Accuracy : 0.2% 

5.

 

CMRR :    60Db 

6.

 

Input, Output Capacity: 5pF ( Under 1k Hz) 

7.

 

Input Impedance (R): Measurement Ux

10V, Ri

Ux

×

1k

Ω

/V

 

Measurement Ux

10V, Ri

Ux

×

10k

Ω

/V

 

8.

 

Linear Range:0-120% of nominal input 

9.

 

Responding Time: 300mS 

10.

 

Over Load Capacity: 2 times of nominal input, continuous; 

11.

 

Maximum Load: 5mA 

12.

 

Static Current: 20mA 

13.

 

Auxiliary Power:+12VDC or +24VDC (optional) 

14.

 

Isolation Voltage:

 ≥

2500Vdc, for 1 minute 

15.

 

Output Ripple: 

40mV (root-mean-square value, output load is 250Ohm) 

16.

 

Drifting by Temperature

200

×

10

-6

/

 

17.

 

Case Protection and Material: IP20; Flame Retarded ABS ( Conform to UL94V-0) 

18.

 

Mean Time Before Failure (MTBF):    50000 Hours 

19.

 

Ambient Temperature:(Commercial grade)

 0

℃~

+50

 

(Industrial grade)

 -25

℃~

+70

 

20.

 

Mounting : DIN Rail 35mm Mounting or M3 Screw Mounting     

 
 
 

Mianyang Weibo Electronics Co.,Limited 

No.7 Road 2 of Xianren Road Youxian District Mianyang City P.R. China     

Tel: 86-816-2971265 Fax: 86-816-2281934 

www.wb-my.com

4

     

[email protected]

 

Summary of Contents for WBV415S01

Page 1: ...ucer TRUE RMS www wb my com wblch wbdz cn Technical Service 86 816 2778271 Quality Complain 86 816 2278273 Fax Line 86 816 2281934 ISO9001 ISO14000 ISO18000 Certified Quality Warranty Any quality problem found in WB series products we offer Three years free charge of repair the products and six months guaranteed free charge of change and return the products ...

Page 2: ... The operating manual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request the necessary informatio...

Page 3: ...t or electric circuit The product has certain advantages of total galvanic isolation between input and output high accuracy low drifting by temperature and wide temperature bearable range etc Function realization schematic drawing In 4 6 5 3 Mianyang Weibo Electronics Co Limited No 7 Road 2 of Xianren Road Youxian District Mianyang City P R China Tel 86 816 2971265 Fax 86 816 2281934 www wb my com...

Page 4: ...nput 9 Responding Time 300mS 10 Over Load Capacity 2 times of nominal input continuous 11 Maximum Load 5mA 12 Static Current 20mA 13 Auxiliary Power 12VDC or 24VDC optional 14 Isolation Voltage 2500Vdc for 1 minute 15 Output Ripple 40mV root mean square value output load is 250Ohm 16 Drifting by Temperature 200 10 6 17 Case Protection and Material IP20 Flame Retarded ABS Conform to UL94V 0 18 Mean...

Page 5: ... 10mV and multiple converters can share with one set auxiliary power together 3 Basic testing method for accuracy 1 According to the terminal definition table to connect the testing circuit 2 The testing must to be done by under the following conditions Auxiliary power 24V 1 ripple 5mV Ambient temperature 25 2 Relative humidity RH 45 75 Accuracy for Signal Power Source instrument 0 05 Signal Power...

Page 6: ...p and fall of the product 4 If the product has been using under the environment with strong magnetic field interference please pay attention to the shield of input wire and the output signal wire should be as short as possible For product intensive installation the space between each product should not be smaller than 10mm 5 Only use identified terminals 6 There is no lightening strike prevention ...

Reviews: