WBV344U01-S DC Voltage Transducer 

Safety claim 

The  information  in  the  safety  claim  of  the  equipment  documentation  is  intended  to  ensure  that 
equipment is properly installed in order to maintain it in a condition. 
It is assumed that everyone who would be associated with the equipment should be familiar with 
the contents of that safety section, or this safety guide. 
When electrical equipment is in operation, dangerous voltages will be present in certain parts of 
the  equipment  (e.g.  the  input  terminal).  Failure  to  obverse  warning  notices,  incorrect  use,  or 
improper  use  may  endanger  personnel  and  equipment  and  course  personal  injury  or  physical 
damage. 
Before working in the terminal strip area, the equipment must be isolated. 
Proper and safe operation of the equipment depends on appropriate shipping and handling, proper 
storage, installation and commissioning, and on careful operation, maintenance and servicing. 
The operating manual for the equipment gives instructions for its installation, commissioning, and 
operation.  However,  the  manual  cannot  cover  all  conceivable  circumstances  or  include  detailed 
information  on  all  topics.  In  the  event  of  questions  or  specific  problem,  do  not  take  any  action 
without  proper  authorization.  Contact  the  appropriate  WB  technical  sales  office  and  request  the 
necessary information.   
 

Standard application 

1. Accuracy 

    Accurate degree is conformed to IEC688:1992 

2. Safety 

  2.1 Overload capability 
        Overload capability is conformed to IEC688:1992 
  2.2 Isolation voltage 
        Can be endured testing voltage is conformed to Q/72085584-0.1-2004 
  2.3 Insulation impedance 
        The  insulation  impedance  is  no  less  than  20M  Ohm,  is  conformed  to 

Q/72085584-0.1-2004     

3. Electromagnetic Capability   
          3.1  RF-Electromagnetic  field  immunity  test  according  to  EN61000-6-2:2005, 

EN61000-6-4:2001 

3.2  Power  frequency  magnetic  field  immunity  test  according  to  EN61000-6-2:2005, 

EN61000-6-4:2001   

3.3  Electrostatic  discharge  immunity  test  according  to  EN61000-6-2:2005, 

EN61000-6-4:2001 

3.4 Surge immunity test according to EN61000-6-2:2005, EN61000-6-4:2001 
3.5  Electrical  fast  transient/burst  immunity  test  according  to  EN61000-6-2:2005, 

EN61000-6-4:2001 

3.6 Conducted disturbance voltage according to EN61000-6-2:2005, EN61000-6-4:2001 

Summary of Contents for WB Series

Page 1: ...nsducer www wbsensor com wbwm wbdz cn Technical Service 86 816 2278271 Quality Complain 86 816 2278273 Fax Line 86 816 2281934 ISO9001 ISO14000 GB T2800 CE Certified Quality Warranty Any quality problem found in WB series products we offer Three years free charge of repair the products and six months guaranteed free charge of change and return the products ...

Page 2: ...nual for the equipment gives instructions for its installation commissioning and operation However the manual cannot cover all conceivable circumstances or include detailed information on all topics In the event of questions or specific problem do not take any action without proper authorization Contact the appropriate WB technical sales office and request the necessary information Standard applic...

Page 3: ... 6 2 2005 EN61000 6 4 2001 Product Description and Application WBV344U01 S converts DC input pure voltage into a load independent output signal DC 0 20mA or 4 20mA It has adopted modulation demodulation isolation principle and average measurement method for real time measurement of DC voltage from electric net or electric circuit The product has certain advantages of total galvanic isolation betwe...

Page 4: ...5 Linear Range 0 120 of nominal input 6 Responding Time 150ms 7 Over Load Capacity 2 times of nominal input continuous 8 Maximum Load Output voltage 10V 500Ω 9 Auxiliary Power 12V 24V 10 Current consumption for static status 17mA 11 Isolation Voltage Input output 2500Vdc for 1 minute 12 Output Ripple 10mV 13 Drifting by Temperature 0 50 2 5 10 4 14 Ambient Temperature 10 50 15 Mounting DIN Rail 35...

Page 5: ...ther precise signal sampling user needs to warm up the product for 3 minutes before use a The auxiliary power requires isolation voltage 2000VAC DC current output ripple 10mV and multiple converters can share with one set auxiliary power together b When measuring dc voltage exceeds 1000volts the circuit needs adding a resistor to divide the input dc voltage The resistor is provided by Weibo Electr...

Page 6: ...the given accuracy value of the transducer it shows the transducer s accurate grade is qualified Caution 1 Pay attention to the auxiliary power information especially the auxiliary power grade and polarity other wise will damage the product 2 Pay attention to the wire connection wrong terminal connection will cause malfunction of the product and even damage the product 3 Don t dismantle the produc...

Page 7: ...atives 7 This product uses fire prevent ABS crust its temperature withstand is only limited as 85 higher than this limitation will cause the product deformation Please use and store carefully 8 This product can t be used to measure the pulse DC voltage signal otherwise there will be more errors or no output Product Input Output characteristic curve Input 0 100 4mA 20mA Input Output characteristic ...

Reviews: