3
Specifications
SPeCIfICATIOnS
ITem
SPeCIfICATIOn
Gen-6000-0mH0/e
Gen-6000-0mS0/e
Gen-7500-0mH0/e
Gen-8000-0mS0/e
Engine
Honda
Subaru
Honda
Subaru
Watts (AC) Rated
5000 watts
5000 watts
6500 watts
6900 watts
Watts (AC) Max.
6000 watts
6000 watts
7500 watts
8000 watts
Rated voltage (AC)
20/240v
20/240v
20/240v
20/240v
Max. Amperage
50.0/25.0
50.0/25.0
62.5/3.3
66.7/33.3
Cont. Amperage
4.7/20.8
4.7/20.8
54.2/27.
57.5/28.8
Frequency
60
60
60
60
Fuel Tank Capacity
7.3 gal.
7.3 gal.
7.3 gal.
7.3 gal.
Run Time Hours /
Tank of Fuel*
8.0 hrs.
7.9 hrs.
6.9 hrs.
6.7 hrs.
Battery for Electric Start
#32-0058
* Rated at Full Load
ReCORd SeRIAl numbeR
Write you model number, machine serial number and date
of purchase in the spaces provided below. Your dealer
needs this information when ordering parts.
Model No. ______________________________________________
Machine Serial No. _______________________________________
Date of Purchase ________________________________________
(To be filled in by purchaser)
NOTE:
Unit ratings are established based on operation at standard conditions of 60° F and at sea level. The
performance of the generator must be de-rated for temperature and altitude by 1% for every 10° F above 60° F
and 3.5% for every 1000 feet above sea level. Due to the operational characteristics of the thermal type circuit
breaker, the power available from the generator will decrease slightly with a corresponding increase in ambient
temperature.
Due to continuing product improvements, specifications are subject to change without notice.