Operator’s Manual
SAFETY WARNING WHEN REFUELING
Gasoline is extremely flammable and its vapors can explode if
ignited.
Observe all safety regulations for the safe handling of fuel. Handle
fuel in safety containers. If the container does not have a spout, use
a funnel.
Do not overfill the fuel tank, leave room for the fuel to expand.
Do not refill fuel tank while the engine is running. Before refueling
the generator, turn it off and let it cool down. Gasoline spilled on hot
engine parts could ignite.
Fill the tank only on an area of bare ground. While fueling the tank,
keep heat, sparks and open flame away. Carefully clean up any
spilled fuel before starting engine.
Always fill fuel tank in an area with plenty of ventilation to avoid
inhaling dangerous fumes.
NEVER store fuel for your generator in the home. Gasoline, propane,
kerosene, and other flammable liquids should be stored outside of living
areas in properly-labeled, non-glass safety containers. Do not store
them near a fuel-burning appliance, such as a natural gas water heater
in a garage. If the fuel is spilled or the container is not sealed properly,
invisible vapors from the fuel can travel along the ground and can be
ignited by the appliance’s pilot light or by arcs from electric switches
in the appliance.
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
These generators are equipped with a GFCI (Ground Fault Circuit
Interrupters) 20V duplex receptacles for protection against the hazards
of electrical shock from defective attachments such as, tools, cords,
and cables.
WARNING: The GFCI may not function unless the
generator is properly grounded. Follow
the correct procedure specified in the section
labeled “GROUNDING INSTRUCTIONS”.
A GFCI is a device that interrupts electricity from either the utility or
generator by means of a special type of circuit breaker if a fault current
flow to the ground occurs.
A GFCI can be used only with generators that have the neutral wire
internally bonded to the frame, and the frame properly grounded to the
earth. A GFCI will not work on generators that do not have the neutral
wire bonded to the frame, or on generators which have not been properly
grounded. All Mi-T-M generators have internally bonded ground wires.
A GFCI will not work if the unit is not properly grounded.
A GFCI may be required by OSHA regulations, the National Electric
Code and/or local and federal codes when operating a generator.
For additional protections against shock hazards due to defective
equipment attached to the twist-lock receptacles, consider the use of
a GFCI on each of these receptacles as well.
GFCI and GFCI protected cord sets and cables may be purchased from
local electrical supply houses.
Summary of Contents for GEN-1100-0MS0
Page 8: ... Operator s Manual Contents ...
Page 38: ...38 Operator s Manual Wire Diagram ...
Page 42: ...42 Operator s Manual Notes ...
Page 43: ...Guide d utilisation 43 Notes ...
Page 50: ...50 Guide d utilisation Table de matières ...
Page 84: ...84 Guide d utilisation Note ...
Page 85: ...Manual del Operador 85 Note ...
Page 92: ...92 Manual del Operador Materias ...
Page 122: ...122 Manual del Operador Diagrama de alambre ...