Thermostat settings (DIP switch)
Using the 4 DIP switches inside the housing (SW1), the following device settings can be made.
Electric floor heating
Water-guided floor heating or
other heat source
Combination of ground and
other heat source
Einstellungen für die
Verwendung des externen
Bodensensors und der
Temperatur-Einheit °C, sowie
der max. Schaltleistung von 10-
16A
Settings for using the internal
room sensor and the
temperature unit °C, as well as
the maximum switching
capacity of 10-16A
Settings for the use of both
temperature sensors and the
temperature unit °C, as well as
the maximum switching
capacity of 10-16A
Description of the DIP switches (1-4):
1 = temperature unit, °C or °F (bottom °F / top °C)
2= Use of the internal room sensor (bottom active / top inactive)
3 = Use of the external floor sensor (bottom active / top inactive)
4 = Selection of the maximum switching capacity of the relay (below 10-16A / above 3-8A)
Provided that the two DIP switches 2 and 3 have been set to the same position, the thermostat works
with both sensors.
If the room is only heated with electric underfloor heating, only operation with the external sensor is
recommended. If the room is additionally heated with another heat source, operation with both
sensors is recommended.