background image

5 Warranty & Recording 

5.1 MI-Fires Stoves Warranty 

Terms & Conditions 

The Firebox of your MI-Fires Stove is Guarantee against manufacturing and material defects for a minimum 
period of 12 months from the date of purchase, you can however extend the warranty period in a number of 
ways. 
 

 

Completing and returning the warranty registration form will increase the warranty to two years* 

 

Installing the stove with an “MI

-

Flues” flue liner or chimney system can extend the 

warranty to ten 

years** 

The Warranty commences on the date of purchase. 

This warranty will only cover consumable parts if the purchaser can prove that they were damaged upon 
receipt of the stove. 

The warranty is non-transferable and is only available to the original purchaser. 

This warranty does not affect your statutory rights. 

In the unlikely event of any failure we will replace any defective part free of charge, labour cost excluded. 

The Stove and Flue system must be inspected, serviced and cleaned on an annual basis by a suitably qualified 
engineer, certificates and receipts must be retained as proof of maintenance.  

Exclusions & Limitations 

The warranty will be void if the appliance is not installed by a suitably qualified person, or is not installed in 
accordance with the current building regulations. 
The warranty will be void if the appliance is modified in any way or assembled incorrectly. 
MI-Flues Ltd will not be responsible for any incidental or consequential loss, damage or injury however caused. 
The following parts are considered as consumable items and as such are not covered by any warranty:- 

 

Glass 

 

Vermiculite insulation panels 

 

Vermiculite baffle 

 

Secondary steel baffle 

 

Door and glass rope seals 

 

Paint finish 

It is a condition of the warranty that the stove is only used in accordance with the installation instructions, and 
is not subjected to misuse or neglect, including the use of non-recommended fuels. 

*   The Warranty registration form is found at the rear of the Installation instruction Manual

** For the context of the warranty, an MI-Flues flue liner or chimney system is described as a complete flue 
system purchased from MI-Flues Ltd or one of its distributors. The complete system must comprise 
exclusively of the correct components taken from the MI-Flues product range 

 

Summary of Contents for Grisedale

Page 1: ...Version 1 2019 sdm Loughrigg Skiddaw Grisedale User Installation Manual BS EN 13240 2001 A2 2004 tested as intermittent appliances burning wood logs www mi fires com ...

Page 2: ...proved Defra smoke exempt and can be used in smoke controlled zones only when the stop is in place and installed in accordance with the current building control regulations Please note this is a wood only stove your new stove has been specifically designed for the combustion of wood and approved wood bricks The use of other mineral fuels are not allowed The appliance should not be used as an incin...

Page 3: ...nt safety information 3 2 The Stove Air Controls 3 3 How should I use my wood burning stove 3 4 Lighting a fire in the wood burning stove 3 5 Important Information for Wood Burning 4 Cleaning and Maintenance 4 1 Chimney Sweeping 4 2 Combustion chamber 4 3 Glass 4 4 Gaskets 4 5 Ash 4 6 Cleaning the stove 4 7 Spare Parts List 5 Warranty Recording 5 1 MI Fires Stoves Warranty 5 2 Installer details an...

Page 4: ...1 Compliance 1 1 Dimensions Loughrigg Skiddaw Grisedale ...

Page 5: ...at 13 O2 Nmg m 103 98 127 DIN Plus Particulates at 13 O2 Nmg m 18 12 14 Distance to Combustible Back mm 300 250 250 Distance to Combustible Sides mm 400 400 400 Distance to Furniture Front mm 1075 1075 1075 Minimum Hearth Distance Front mm 400 400 400 The results stated were obtained when burning wood logs 1 3 Transportation When taking your wood burning stove home please ensure that it travels in...

Page 6: ...s Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met 2 2 Position of the stove Distance requirements The wood burning stove must be installed in a suitable and physically possible position You need to be sure that the position complies with local regulations Please ensure if the stove is placed in a fireplace recess it is ad...

Page 7: ...chimney draft of 10 14 Pascal Pa measured in the flue pipe above the stove However with natural draft the draft in the chimney will be between 18 25 Pa when conditions are optimum There are many factors that affect the chimney draft including the outside temperature wind strength and surrounding buildings The minimum flue height requirement is 4 5 metres if this cannot be achieved you will have to...

Page 8: ...authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England ...

Page 9: ...se wait to empty the ash until you are sure that there are no embers in the ash The door should be kept closed while the wood burning stove is in use While lighting the fire the door can stand ajar for the first few minutes In the event of a chimney fire Close all the dampers on the wood burning stove and call the fire fighting service Your installer should have fitted a CO alarm in the same room ...

Page 10: ...wn to embers before new logs are added To obtain the best possible combustion you should regulate the effect heat output with the fuel and Air Burning small logs provides more powerful combustion than burning large logs as the surface area is greater and more gas is released The amount of wood in the combustion chamber is another factor that affects combustion The optimum combustion is achieved by...

Page 11: ...e tertiary air inlet profiling in the rear vermiculite firebox liners at the back of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning Burning without flames above the fuel will create unnecessary smoke After re fuelling open the primary air control fully for 3 minutes or until the logs are fully blackened to achieve full flames above the fuel...

Page 12: ... g the Aduro Easy Clean pad The pad neither scratch nor damage the glass and is for multiple usages Water or other cleaning agents are not necessary It is common maintenance to tighten the glass fittings shortly after the stove has been installed as well as to check if the gaskets are properly placed 4 4 Gaskets With time gaskets around glass and door will wear We recommend that you inspect them r...

Page 13: ...6 S VBP 236 M VBP 236 L VBP VERMICULITE FIRE BOX LEFT 236 S VFBL 236 M VFBL 236 L VFBL VERMICULITE FIRE BOX RIGHT 236 S VFBR 236 M VFBR 236 L VFBR VERMICULITE FIRE BOX BASE 236 S VFBB 236 M VFBB 236 L VFBB VERMICULITE FIRE BOX BACK LEFT 236 S VFBBL 236 M VFBBL 236 L VFBBL VERMICULITE FIRE BOX BACK RIGHT 236 S VFBBR 236 M VFBBR 236 L VFBBR AIR CONTROL 236 S AC 236 M AC 236 L AC HANDEL CHROME 236 HC...

Page 14: ...s and receipts must be retained as proof of maintenance Exclusions Limitations The warranty will be void if the appliance is not installed by a suitably qualified person or is not installed in accordance with the current building regulations The warranty will be void if the appliance is modified in any way or assembled incorrectly MI Flues Ltd will not be responsible for any incidental or conseque...

Page 15: ...nstallers Contact Details H E T A S Number Date of Installation Appliance serial number Flue Draft test completed Yes No Pascal Rating Type of Flue system diameter Unlined Masonry Lined Masonry Clay pot Insulated Twin wall system Flue system Manufacturer Installation instructions left with customer Yes No ...

Page 16: ...5 3 Annual Service Sweeping record DATE ENGINEER SWEEP NAME CERTIFICATE RETAINED ...

Page 17: ...is form and return it to MI Flues Ltd MI Fires Warranty Registration Taymin Business Park Mitcham Road Blackpool Lancashire FY4 4QN Your Details Name Address Postcode Contact Number Email Model Name Serial Number Installation Date Installer Name Installer H E T A S Registration No ...

Page 18: ......

Page 19: ......

Page 20: ...Mi Flues Ltd Taymin Business Park Mitcham Rd Blackpool Lancashire UK FY4 4QN Tel 01253 600060 Fax 01253 600061 sales mi flues com sales mi fires com ...