Installing the Blower
1. Remove the plate located in front of the glass at the bot-
tom.
2. Remove rod provided for screen assembly located
beneath the cover plate.
3. Rotate the access doors on the right and left side of the
glass toward the glass.
4. Remove glass frame by releasing the three latches located
at the top of the firebox. Tilt glass away from the unit, lift
glass frame up and away from the unit.
Figure 2
5.
Replace side panels attached to the glass frame as-
sembly with the louvered side panels provided with
the blower kit by unfastening the four nuts for each
cover door. (Do not overtighten or stud may break
off.) Use three metal clip screws provided with kit to
secure the wire assembly in the front beneath the
access cover.
Figure 3
NOTE
Keep wires away from
combustion chamber
and blower wheel.
FP2549
glass frame removal
Figure 2 -
Remove Glass Frame
Glass
Frame
FP2549
Figure 3 -
Install New Louvers
FP2234
install louvers
1/09
Remove Solid
Access Door
Replace with Louvered Access
Door, Louvers Towards Bottom
FP2234
6. Remove the four (4) screws securing the light box on control
side of unit.
7. Remove brick wall panel from firebox wall.
8. Remove blower access panel from firebox wall.
Figure 4
9. Disassemble blower mounting bracket from blower access
panel.
Figure 5.
Mount blower to mounting bracket with the
supplied #8 sheet metal screws. The blower may be mounted
on either side of unit according to where the owner would
like the discharge to be.
10.
Wiring for one (1) blower:
Attach the two (2) female con-
nectors from A/C Module marked ‘Blower’ to the two (2) male
connectors on blower.
Figure 6.
Wire clip on blower mounting
bracket can be used to route wires away from blower blades.
NOTE:
Discard wire harness for one blower installation.
Wiring for two (2) blowers:
There is one (1) wire harness
supplied with each blower kit. Attach the two (2) female con-
nectors from one wiring harness to one (1) male connector on
each blower. Repeat with the second wiring harness. Attach
the two (2) male connectors from the wiring harness to the
female connectors from the A/C Module marked ‘Blower’.
Figure 7
11. Reassemble blower access panel with blower(s) installed
into firebox.
12. Replace brick wall panel.
13. Replace glass frame.