MHSC BLOTKSTSC Installation Instructions Download Page 1

Blower 
Installation Instructions
Model: BLOTKSTSC

For Signature Command Systems

Before You Start

The BLOTKSTSC Blower Kit is designed to be installed with the Signature Command System with 
the SCSACM A/C control module and is controlled only with the RFSC remote control. 

NOTE:

 This instruction sheet is ONLY for models listed below. Carefully inspect the contents for 

shipping damage. If any parts are missing or damaged, immediately inform the dealer from whom 
you purchased the part.

Models:

 KSTDV/DVKST

NOTE:

 This kit contains only one blower, however, two (2) blowers may be installed if desired as 

shown in Figure 2. An additional BLOTKSTSC blower kit must be purchased.

Kit Contents:

 

1, Blower 

1, Louvered Access Panel, Right

 

1, Wire Harness 

1, Louvered Access Panel, Left

 

4, #8 Sheet Metal Screws

Tools Required:

 

 

Short handle Phillips screwdriver

W

ARNING

Before  installing  the  blower,  turn  off  the  fireplace 
and allow to cool. Only a qualified service person 
should service and repair the fireplace. A qualified 
service person should connect and disconnect the 
fireplace to gas supply. Follow all local codes.

W

ARNING

Electrical Grounding Instructions:

This  appliance  is  equipped  with  a  three-prong 
(grounding) plug for your protection against shock 
hazard and should be plugged directly into a prop-
erly grounded three prong receptacle.

CAUTION

Electrical  connections  should  only  be  performed 
by  a  qualified  licensed  electrician.  Main  power 
supply must be turned off before connecting fans 
to the main electrical power supply or performing 
service.

IMPORTANT:

 Always check local building codes. This 

installation must comply with local regulations as well 
as the National Electric Code.

Installation Instructions
Wiring

1.  Before installing the blower, wire the receptacle into an electrical 

circuit. This should be done before framing the fireplace. Wire with 
minimum 60° C wire in accordance with prevailing codes.

2.  Remove the external junction box cover by removing the screw 

from the left side of the outside firebox wall. Junction box was 
installed at the factory.

3.  The junction box cover has a factory installed “romex” style strain 

relief connector. After connecting the wires, route the wire leads 
through this connector. Refer to the wiring diagram in Figure 5.

73D4166  11/09  Rev. 1

FP1912
Junction box wiring
8/08

Junction Box

120V AC
60Hz

Factory Supplied

Not Supplied

Figure 1
Junction Box Wiring Diagram