Lo-Rider Vent Free Fireboxes
CLEARANCES and HEIGHT REqUIREMENTS
Ensure that minimum clearances shown in
Figures 3
through 7
are maintained. Left and right clearances are
determined when facing the front of the firebox.
Follow these instructions carefully to ensure safe instal-
lation. Failure to follow these requirements may create a
fire hazard.
1.
Sidewall Clearances
— The clearance from the inside
of the appliance to any combustible adjacent wall should
not be less than 5
B\,
".
Figure 3
.
Ceiling Clearance
— The ceiling must be at least 4"
from the top of the firebox opening (bottom of hood).
Figure 3
3.
Back Wall Clearance
— The appliance may be placed
against a combustible back wall.
4.
Parallel Wall Clearance
— The clearance from the
opening of the firebox to any wall that is parallel to the
opening should not be less than 36" (36STFL and 36PFL
models only).
Figure 4
42”
FP2886
see thru clearances
5
6
”
Figure 3 -
Sidewall and Ceiling Clearances
FP886
36”
FP2887
parallel clearances
Figure 5 -
Hearth Dimensions
FP887
Figure 4 -
Parallel Wall Clearance
(LSTF36 and LPF36 Models Only)
A
B
C
FP2888
hearth dims
A
B
C
See-thru
33
C\zn
"
1
ZB\zn
"
7
C\v
"
Corner
35
C\zn
"
1
ZB\zn
"
7
C\v
"
Peninsula
35
C\zn
"
1
ZB\zn
"
7
C\v
"