Position the bracket      

a

    and insert the screws with washers. Then tighten the screws::

8.  

Position    

d

    upper plastic parts of the bracket:

9.  

Fit the two    

e

    lower clamps and rotate them until you hear a first click.

10. 

Position the radiator by leaning it on the upper part of the brackets and then rotating it. Push the radiator until it is 

automatically locked by lower plastic clamps    

e

    .

The operation is over only when locking hooks are blocked and the radiator is fixed on the wall, 

without any possibility of movement.

In any case the minimum distance of the radiator from the floor must be 100 mm.

d

d

e

e

Clack

!

d

e

Summary of Contents for DECORAL ELECTRIC WIFI

Page 1: ...INSTALLATION USE AND MAINTENANCE MANUAL DECORAL ELECTRIC WIFI ALUMINIUM FLUID FILLED ELECTRIC RADIATOR...

Page 2: ...THEAPPLIANCE 26 3 1 RADIATORWALLMOUNTING 26 4 ADJUSTMENTANDPROGRAMMING 29 4 1 CONTROLPANEL 29 4 2 FIRSTSTART 29 4 3 DESCRIPTIONOFOPERATINGMODES 30 4 3 1SIMPLE MANUAL MODE 30 4 3 2PROGRAMMODE 30 4 3 3T...

Page 3: ...ceunlesstheyaresupervised Childrenagedbetween3and8canonlyturntheradiatoronoroff providedthatitispositionedproperly andthatchildrenhavebeentaughtthesafeuseoftheapplianceandhaveunderstoodthepossible cor...

Page 4: ...e between contacts shall beatleast3mm Itiscompulsorythatthepowersupplycircuitoftheapplianceisprotectedbyahighsensitivitydifferentialprotectiondevice Donotintroduceanddonottrytopenetratewithmetalobject...

Page 5: ...pectadistanceofatleast30cmfromthetopedgeoftheradiatorandtheshelfaboveit 30 cm 3 1 RADIATOR WALL MOUNTING Theradiatormustbefastenedtoawallthroughthesuitablemountingbracketsprovidedwiththeproduct Thefas...

Page 6: ...lowerslotsofthebracketmatchthemarks T1 and T2 5 Usingaspiritlevel checkthatthebracketisstraightandmarkthepositionofthetwoupperholes U1 and U2 6 Dependingonthetypeofwall selectsuitablescrewsanddowels t...

Page 7: ...untilyouhearafirstclick 10 Positiontheradiatorbyleaningitontheupperpartofthebracketsandthenrotatingit Pushtheradiatoruntilitis automaticallylockedbylowerplasticclamps e Theoperationisoveronlywhenlocki...

Page 8: ...sitiontheswitchto0 Whentheradiatorisswitchedonagainusingtheswitch thenewsettingofcurrent dateanddaymayberequired Use the knob 2 to select the operating mode and increase or decrease the set values pre...

Page 9: ...erature turntheknobandconfirmbypressingit 4 3 2PROGRAM MODE Whentheapplianceisinthismode theradiatorfollowstheprogramdefinedforeachdayoftheweek Uponthefirstswitching on thefollowingprogramispreset Fir...

Page 10: ...ion Themaximumdefaulttemperatureis30 C butitcanbechangedusing MAXTEMP parameterofPARAMETERS LIMITATIONSmenu Theminimumconfigurabletemperatureis12 C belowthisvaluetheappliancesetstothefreezeprotectiont...

Page 11: ...eweekcanbeprogrammedseparately andforeachday3operatingtimeslotscanbeconfiguredinComfortmode dependingonyourneeds Ifyoudonotwishtouseallthe3timeslots simplydonotselectthem Thetimeslotyouareselectingiss...

Page 12: ...ASCisnot displayed ThePilotWireistheblackwireinsidethepowercable usedinFranceforcontrolfromremotecontrolunit seeparagraph 2 Electricalconnections 5 TemperatureCALIBRATION allowscalibratingthetemperatu...

Page 13: ...30minutes Ifthishappens theradiatorswitchesofffor30minutesandthenitrestartsworking inthepreviouslysetmodeifitdetectsasubsequentincreaseintemperatureofatleastonedegreecentigrade thewindowhas beenclosed...

Page 14: ...ONandOFF selectONtoswitchtheradiatorbackon Adoubleshortbeepsignals theswitchingon 4 11 WI FI CONNECTION You can manage your radiator heating system from your smartphone through theWi Fi of your home a...

Page 15: ...uraccount Afterdownloading openthe DomusOne APPonyourphone If you open the APP for the first time you have to register to the DomusOne platformbycreatinganewaccount thisisnolonger requiredifandwhenyou...

Page 16: ...illbepromptedtoframetheQRcodeontherightsideoftheradiator FrametheQRcode amessagewillappearonyourphone press CONNECT Youwillbepromptedtogiveanametotheradiatorandpairittoagroup forexampleyoucangivethena...

Page 17: ...nshowsthetemperature thatcanbechangedbypressing or orslidingthecursor Thelowerpartofthescreenshowstheselectableoperatingmodes theactivemodeiscoloured theothermodesaregrey Press the icon in the upper r...

Page 18: ...PROBABLECAUSE SOLUTION Theradiatordoesnotheat Thedisplaydoesnotshow anynotice Nopowersupply Checkthatthereisvoltage andthattheradiatorswitch isinIposition RadiatorinPROGRAMmode Theprogramprovidesfor...

Page 19: ...heroom This situationdoesnotlegitimate thereplacementofthe radiatorunderwarranty Theradiatoristoohot Radiatorinheatingphase Theradiatornormallyrea cheshightemperatures Hightemperaturescomply withsafet...

Page 20: ...ly 8 ENVIRONMENT The symbol applied to the appliance and shown here indicates that the product must be disposed of in separate collection for electricalequipment Attheendofthelifeoftheappliance itcann...

Page 21: ...connecteachradiatortotheInternetandpairittoyour personalaccount Youcanaddnewradiatorstoyourpersonallistatanytimeandgivethemanametoeasilyrecognisethem N B alltheradiatorsareproducedwithanidentification...

Page 22: ...utput Pmax c 0 75 1 0 1 25 1 5 1 8 kW withmechanicthermostatroomtemperaturecontrol No Auxiliaryelectricityconsu mption withelectronicroomtemperaturecontrol No Atnominalheat output elmax 0 75 1 0 1 25...

Page 23: ...tricalEquipment Safety Regulations2016andamendments ElectromagneticCompatibilityRegulations2016andamendments TheRestrictionoftheUseofCertainHazardousSubstancesinElectricalandElectronic EquipmentRegula...

Page 24: ...imited Unit 4 Genesis Endeavour Drive Basildon SS14 3WF Tel 0345 521 5666 Fax 01268 888260 orders mhsradiators co uk enquiries mhsradiators co uk mhsradiators co uk SALES OFFICE 0345 521 5666 AFTERSAL...

Reviews: