NOTE:
The purchaser and users must initially and continually satisfy themselves
that the installation on their particular equipment, and for their circumstances, is
air-worthy and provides an ongoing appropriate and secure oxygen delivery system
with adequate oxygen cylinder pressure prior to each flight. Oxygen masks should
be on board and ready for use in the case of failure of the cannula or it’s mounting.
In case of failure of the mounting system, the cannula can be held in place in the
mouth and oxygen delivered by mouth breathing.
INSTRUCTIONS
NOTE:
Take the time to read these instructions to get it right the first time!
The MH E-Z Breathe II™ Boom Cannula is supplied with uninstalled components.
Installing your E-Z Breathe II™ Boom Cannula is easy and should only take five
to ten minutes to do it properly. Once the mount has been correctly installed and
adjusted, the E-Z Breathe II™ Boom Cannula was designed to allow the user to
pivot the cannula out of the way or be removed by loosening the friction thumb
screw and carefully snapping the arm off the ball mount when not needed.
INSTRUCTIONS FOR MOUNTING YOUR BOOM CANNULA
•
A good cleaning with isopropyl alcohol is critical to the long term durability of
the adhesive bond.
•
Avoid temperatures below 50° F. when mounting the components.
•
If a bond failure occurs,
DO NOT
use harsh solvents to remove the adhesive.
•
Maximum bond strength occurs within 72 hours of application.
However with care, it can be used immediately.
•
If Ball Mount needs to be repositioned, it will be necessary to replace the
adhesive pad.
•
For more detailed installation notes, photos and tips, visit our website at:
www.MHoxygen.com
•
FIRST
(fig. 1)
Establish the optimum position on
the outside face of the ear cup at
a location with the minimum cur-
vature. Wipe the area clean with
the supplied alcohol wipe as well
as the flat area on the ball mount.
With a pencil, trace the outline of
the desired ball mounting position
on the ear cup.
(1)
(2)
(3)
(4)
(5)
•
NEXT (fig.2)
Remove the adhesive protective covering
from one side of the adhesive pad. Place
the adhesive pad in the area marked
and press firmly to adhere the pad to the
headset.
•
THEN
(fig. 3)
Remove the other adhesive protective
covering from the adhesive pad.
•
THEN (fig. 4)
Firmly press the ball mount onto the
adhesive pad.
•
FINALLY (fig. 5)
Loosen the friction thumb screw, snap
the ball receiver end onto the ball and
adjust the thumb screw as needed.
Then adjust the nose piece and tubing
by sliding in or out so it fits comfort-
ably .... then gently push the arm up
and out of the way ..... it is now ready
to use when needed.