15-00043
Revision
3
September
2005
The publication, translation or reproduction, either party or wholly, of this document are not allowed without our written consent.
35
Table A1-1: Data Format
1 LF
Line
Feed
2 N5
3 N4
4 N3
5 N2
6 N1
7 N0
Dosimeter Serial Number
N5N4N3N2N1N0
8
Status 1 MSB
9
Status 1 LSB
Dosimeter’s dose and dose rate alarms and status.
10 D5
11 D4
12 D3
13 D2
14 D1
15 D0
16 D-1
Accumulated Dose
D5D4D3D2D1D0.D-1 mrem
17 0
Not
used
18
STATUS 5 (MSB)
19
STATUS 5 (LSB)
Configuration Parameters
20 X
1
21 Y
1
22 Z
1
23 T
1
Gamma Dose rate
X,YZ * 10
T
mrem/h
24
Status 3 MSB
25
Status 3 LSB
Dosimeter dose and dose rate warning alarms and status
26
READER # (MSB)
27
READER # (LSB)
Last reader seen in marker mode
28
LIM 0
Limit for Zone 0
29
LIM 1
Limit for zone 1
30
STATUS 10 (MSB)
31
STATUS 10 (LSB)
Dosimeter configuration for secondary measurement
32 COUNTS
(MSB)
33 COUNTS
(LSB)
34 D5
35 D4
36 D3
37 D2
38 D1
39 D0
40 D-1
Accumulated beta dose if enabled.
D5D4D3D2D1D0.D-1 mrem
41 0
Not
used
42 X
2
43 Y
2
44 Z
2
45 T
2
Beta Dose rate
X,YZ * 10
T
mrem/h
46 CKS
MSB
47 CKS
LSB
Checksum
48 CR
Carriage
Return