10 Operating the alarms
The alarm output can be used to switch an external alarm indicator. The external alarm switch is an open collector tran -
sistor switch to ground with a maximum rating of 0.25A DC. It is possible to wire the alarm contacts of several Stratomas -
ter instruments in parallel should this be desired. To avoid false activation of the alarms, the alarm function is only active
10 seconds after the instrument has powered up.
11 Firmware Upgrading
The AHRS-1/ AHRS-3 / MAG-1 can be upgraded in the field by connecting the RS232 port to a PC and running the
firmware update program.
Note that only the RS232 port can be used to upgrade the firmware.
Please see the Vega firmware upgrading document for more information.
12 Installation
AHRS-3
The Tilt Compensate function must be done after the installation of the AHRS-3 has been completed. This allows installa-
tion of the AHRS-3 at angles other than vertical (face). The tilt compensation only needs to be performed once.
12.1 Cable connections
Main connector (D15HD connector: Unit Female, Cable Male)
D15HD Pin
Color
Function
1
Red
8-30Vdc power via power switch / circuit breaker
and fuse.
2
Black
Ground
3
-
RS232 Transmit data (Firmware upgrading)
4
White/Black
Stripe
RS232 Receive data (Firmware upgrading /
NMEA GPS Input)
12
Purple
CAN Low
13
Pink
CAN High
15
White
Alarm Output (Open collector)
Note:
Please see corresponding SP-X sensor package manuals for more information about the
installation and use of the artificial horizon and compass.