9.3 Connection diagram for a Rotax 912
9.4 Extending leads of thermocouple probes
Thermocouple leads as used with the EGT and CHT probes can be extended either with ordinary copper cable or with
special K-Type extension cable. The choice of either depends on your desired accuracy. If it is possible in your installation
to ensure that both ends of a copper extension cable will be at the same temperature (or very close), then it is quite
possible to use the copper cable. In most open-air installations this will be the case. Should this not be possible or you
require best possible accuracy at all times, you can obtain a special K-type extension cable. This cable is made from the
same metals as your probes cable and uses ordinary plastic sleeving as insulation. In either case, ensure that the cable is
not routed close to sources of electromagnetic interference of any kind. The voltages present in this cable are very small
and are subject to changes applied by external fields. This can lead to false temperature indications. You can check your
installation by using a hand-held transmitter, such as an air band radio. If you transmit a signal, no change in temperature
reading should occur.