6
Operating and instruction manual
Compressor does not reach
set pressure and overheats
easily.
Inlet air filter is blocked.
NOTE: It is possible that more
air is being required than
compressor is capable.
Open the compressor and replace oil
filler/air filter plug.
(as recommended
in every 12 months maintenance)
Air leaking from pressure
switch valve when
compressor is not running.
Faulty non-return valve.
First drain all air completely from
receiver. Clean or replace the non-
return valve.
Air pressure from regulator
does not adjust.
Pressure switch is defective
Pressure reducer is defective
Replace the pressure switch
Replace the pressure reducer
Compressor operating, but
no air from outlet.
Inlet air filter blocked.
Bleed pipe (from pressure
switch to non-return valve)
broken or disconnected.
Replace oil filler/air filter plug.
Reconnect or replace bleed pipe.
SPECIFICATIONS
MGF
code
Model
description
Air
displacement
Air delivery*
Motor
Voltage -
frequency
Air receiver
Lt/min CFM Lt/min CFM HP Watt V
Hz
Lt.
S-OF050
Beverage
compressor
12
0.41
6
0.22 0.15 110 230 50 Not present
MGF
code
Model
description
Noise level
Max pressure
Dimensions
Net weight
dB/1m
bar
PSI
mm
kg
lb
S-OF050
Beverage
compressor
55
8
116
200x180x220
5
11
Different voltages-frequencies are available on demand
*