with the other hand, pull the elasticated head 

harness over the back of the head, locating the 

harness centrally on the head.

  Tighten both lower straps evenly towards back of 

head.

  On achieving a face seal, inhale to activate the 

breathing air supply. The duration of the cylinder 

air begins from the time of the first-breath 

activation of the lung demand valve. 

  Breathe normally and immediately leave the 

hazardous area by the shortest and safest escape 

route.

  Once in a safe breathing environment, carefully 

remove the face mask. DO NOT drop or throw 

down the equipment.

 

  Press the reset button on the front of the mask to 

switch off the air flow through the lung demand 

valve.

  NOTE - Correct fit of the face mask can only be 

achieved if the complete mask seal contacts the 

skin. Head hair, facial hair, earrings, other piercings 

and normal spectacles will interfere with the face 

mask seal and are not permitted in the sealing area.

6. AFTER USE

 

• 

Once an emergency escape set has been used 

please return it to MGF for disinfecting, servicing, 

maintenance and to have the cylinder recharged.

1. IMPORTANT NOTES

• 

 For the use of MGF supplied equipment only.  

  Ensure potential users are confined spaces trained, 

familiar with the operation of this equipment and that 

a site specific safe system of work is in place and 

adhered to. 

  Users should comply with the Confined Spaces 

Regulations 1997 and HSE ACOP L101 (2009). 

  It is essential site specific risk assessments are 

undertaken. 

  If in doubt concerning the integrity of any part of the 

equipment DO NOT USE IT. 

  DO NOT open the equipment except in an emergency. 

  The Dräger PP series conforms to EN 402:2003 and 

ISO 23269-1:2008 and meets the requirements of 

89/986/EEC, 97/23/EC, 96/98/EC and is ‘CE’ marked. 

(Use real ‘CE’ marking)

2. DRAGER PP10 AND PP15 EMERGENCY ESCAPE 

SETS

 

• 

You have been provided with a Dräger PP10 or PP15 

emergency escape breathing set that provides 

respiratory protection to escape from a contaminated 

or oxygen deficient environment to a safe breathing 

environment. 

 

 The respiratory protection equipment is contained 

within a carry bag complete with a neck strap. 

 

 The air cylinder is fitted inside the carrying bag but 

has a pressure gauge (Figure 1) that is visible outside 

the bag. 

 

 The PP series comes complete with a face mask to 

supply air to the wearer. 

 

 The PP10 version has a 2 litre aluminium cylinder 

with a nominal duration of 10 minutes and the PP15 

version has a 3 litre steel cylinder with a nominal 

duration of 15 minutes.

 

• 

Ensure that the time required to allow the wearer 

to escape to a safe area is within the capacity of 

the equipment and that the equipment supplied is 

suitable for the job in hand.

3. MGF VISUAL INSPECTION/FUNCTIONAL TEST

 

 All Dräger emergency escape sets supplied by MGF 

are subject to a 6 monthly thorough visual inspection 

or functional test on an alternate basis by competent, 

Dräger trained and approved technicians. 

  Air cylinders are removed from service every 5 years 

in order to be hydrostatically tested. 

  Control valves are replaced every 10 years. 

  Using one hand hold the mask on to the face and, 

mgf.co.uk

 

•  MGF use only Dräger approved parts for maintenance 

and servicing of emergency escape sets.

4. VISUAL INSPECTION - PRIOR TO USE

 

• MGF recommend that the Dräger PP10 emergency 

escape sets are inspected by the user prior to every 

use. As a minimum check that: 

•  The pointer of the cylinder pressure gauge (Figure 

1) is inside the green area. The cylinder should be 

returned to MGF for charging if the pointer is in the 

red area. Very low temperatures may affect this 

reading. 

•  Check the anti-tamper tag on the lid of the bag 

(Figure 2).  If the tag is broken please inform MGF 

and do not use the equipment.

•  Check escape equipment for signs of any damage or 

wear and if damage is evident please inform MGF. 

5. INSTRUCTIONS FOR USE 

•  Your Dräger PP10 or PP15 emergency escape set has 

been supplied ready for use.

•  Putting on the carrying bag: Place the neck 

strap over the head and adjust the strap until the 

equipment sits in the centre of the chest.

•  Putting on the face mask and escape procedure: Grip 

the loop on the lid of the carrying bag and pull firmly 

upward to break the anti-tamper tag and open the lid 

of the bag.

•  Remove the mask from the carrying bag. 

Figure 1

Figure 2

Figure 3