![MGF 905200 User Manual Download Page 9](http://html.mh-extra.com/html/mgf/905200/905200_user-manual_1783156009.webp)
Switching on, there is “hum”, but the motor doesn’t turn:
immediately turn off the motor, and verify if the pump isn’t
locked. Check if voltage in the electric net is corresponding with data on the label. Remember that long power cords may
cause voltage losses. Verify voltage at the pump plug.
The motor stops suddenly:
thermal protection has switched off the pump for too high temperature. Check if voltage is
correct, if pump shaft isn’t blocked or hard to turn. Wait ten minutes, then restart pump.
The motor don’t start:
check electrical connections, plug and switch. If necessary, wait for thermal switch restarting.
Spare Parts
Spare Parts
EXPLODED VIEWS
9
MGF
MGF
srl –– Via Chico Mendes, 8 – 43055 Mezzani (PR) ITALY –
Tel. +39 0521-818301 – Fax +39 0521-818202
E-mail:
– Web:
www.mgftools.com
–
www.nebulizzare.com