MGF 905200 User Manual Download Page 1

This manual has been written according to following directives: 

 98/37/EEC, 2006/42/EEC, UNI-EN 10893 

1

MGF

MGF

 

 

srl –– Via Chico Mendes, 8 – 43055 Mezzani (PR) ITALY –

 

Tel. +39 0521-818301 – Fax +39 0521-818202 

E-mail:

[email protected]

 – Web: 

www.mgftools.com

 – 

www.nebulizzare.com

Art. 905200 – 905250 

PRESS Testing Pump

User Manual

rev. 2.0 del 08/10/2018

Summary of Contents for 905200

Page 1: ...8 37 EEC 2006 42 EEC UNI EN 10893 1 MGF MGF srl Via Chico Mendes 8 43055 Mezzani PR ITALY Tel 39 0521 818301 Fax 39 0521 818202 E mail info mgftools com Web www mgftools com www nebulizzare com Art 905200 905250 PRESS Testing Pump User Manual rev 2 0 del 08 10 2018 ...

Page 2: ...The pump can work with all kind of liquid with a maximum viscosity of 1 5 m Pa s and with water solutions with PH between 7 and 12 MGF MGF refuses every responsibility for damages or bad working if the pump is used incorrectly for a purpose for which it was not intended or is tampered General Informations General Informations Art Modello 905200 PRESS Testing Pump 60 bar 230V 905250 PRESS Testing P...

Page 3: ... covers any manufacturing defect for a period of time equal to one 1 year from the date of manufacture for products purchased with invoice 2 years for products purchased by private individuals The following clauses expressly exclude the product from guarantee Consumables such as pipes impellers to the extent that the malfunction is caused by normal wear and tear of the parts Malfunctions caused by...

Page 4: ...n cords that are also suitable for outdoor use The use of an extension cable suitable for outdoor use reduces the risk of electric shock 7 Make sure that the socket is protected by a differential switch circuit breaker The use of a fault current safety switch reduces the risk of electric shock 3 People safety 1 Working paying attention and with awareness 2 Do not work when you are tired or under t...

Page 5: ...y specialized and qualified personnel and only with original spare parts This ensures product safety even after repair 2 Keep the machine in a correct state of maintenance carrying out and carrying out calibrations and maintenance according to the scheduled maintenance plan A non maintained machine is more dangerous and is not protected by warranty Warnings for the use of the machine 1 Hold or tig...

Page 6: ...acids For example petrol oil alcohol or solvents Vapors or liquids may ignite or explode Acids can damage the machine 18 Do not operate the machine in potentially explosive atmospheres Vapors or liquids may ignite or explode 19 Protect the machine from frost The appliance may be damaged In case of risk of freezing run the empty the system program 20 Use the transport wheels to move the machine 21 ...

Page 7: ...ximum allowed temperature for incoming water is 60 C Connection requires an hose of at least Ø 13 mm internal and 15 bar Shorten if possible the connection hose and eliminate every bottleneck on the hose Minimum flow rate is 10 L min Power connection before connecting check if the electric plant respects safety requirements and if it is able output required power The plant must have safety switch ...

Page 8: ...lation Verify that motor can have right air flow from the chassis Check inlet filter before every test Change oil after 50 hours and then after 100 hours Use MGF MGF mineral oil see below This maintenance timing can change with harder working conditions Art Description 790051 Oil for MGF MGF Pumps 5 L tank 790050 Oil for MGF MGF Pumps 0 5 L bottle If you don t use the pump for a long time and or i...

Page 9: ...s suddenly thermal protection has switched off the pump for too high temperature Check if voltage is correct if pump shaft isn t blocked or hard to turn Wait ten minutes then restart pump The motor don t start check electrical connections plug and switch If necessary wait for thermal switch restarting Spare Parts Spare Parts EXPLODED VIEWS 9 MGF MGF srl Via Chico Mendes 8 43055 Mezzani PR ITALY Te...

Page 10: ...10 MGF MGF srl Via Chico Mendes 8 43055 Mezzani PR ITALY Tel 39 0521 818301 Fax 39 0521 818202 E mail info mgftools com Web www mgftools com www nebulizzare com ...

Page 11: ...er The disposal fee has already been paid if requested COMMISSIONING AND DISMANTLING Before permanently putting the system out of service empty Twister from any chemical product and arrange to deliver it to an authorized waste disposal center for free collection Conformity Declaration Conformity Declaration MGF MGF srl Via Chico Mendes 8 43055 Mezzani PARMA ITALY declares that test pump art 905200...

Page 12: ...12 MGF MGF srl Via Chico Mendes 8 43055 Mezzani PR ITALY Tel 39 0521 818301 Fax 39 0521 818202 E mail info mgftools com Web www mgftools com www nebulizzare com ...