background image

1

Art. 905100

ELECTRIC PRESSURE 
TESTER

User Manual

Rev. 1.0 of 02/08/2016

Summary of Contents for 905100

Page 1: ...1 Art 905100 ELECTRIC PRESSURE TESTER User Manual Rev 1 0 of 02 08 2016 ...

Page 2: ...h a serial id number and technical data 2 Check all working contidions and verify if they allows you to work in safe way lighting humidity temperature wind 3 Before connecting to the mains check that electrical requirements reported on the label are satisfied by the mains same Connect to a plant equipped with differential switch or similar safety devices If you need to use long power cords ensure ...

Page 3: ...lose bypass valve and fill the plant with the water and outflow all air or gases in general inside plant Turn press valve in order to reach requested pressure then close test instrument valve and open bypass lever During the test you can leave test instrument on the plant and disconnect the pump Using differents test instruments it s possible to make different parallel test using only a pump Filli...

Page 4: ...ng maintenance causing damages to peoples and things Working the pump has an acoustical power lower than 83dBA This is an electrical tool respect general electrical devices safety instructions disconnect the pump after working and before maintenance don t let water enter in contact with the electrical parts The pumps guarantee loses its validity if this booklet instructions aren t respected Mainte...

Page 5: ...If necessary contact our technical helpdesk The pump doesn t turn Check if the bypass valve is open Check starting capacitor If necessary contact our technical helpdesk The pump cannot reach requested pressure Verify for losses on plant close pressure regulation valve If necessary clean inlet filter In a second time check for valve wearout or dirty If you need one use only original spare parts Low...

Page 6: ... A A Benzyl A D Butyl A A Diacelone D D Ethyl A A Hezyl A A Isobutyl A C Isopropyl A C Methyl C B Octyl A B Propyl A A A very good B good C poor D not allowed Conformity Declaration Conformity Declaration The Manufacturer MGF MGF srl Via Mendes 8 43055 Mezzani PR ITALY declares that pressure testers 905100 are manufactured according with 2006 42 EEC regulations ing Francesco Maioli 6 ...

Reviews: